TEST_CASES/TWO_RECTANGULAR_CONDUCTORS/rectangle.cable_spec
1 | 1 | #MOD_cable_lib_dir |
2 | 2 | ./ |
3 | 3 | Flex_cable |
4 | +1 # number of conductors | |
5 | +10 # number of parameters | |
6 | +1.1e-3 # parameter 1: dielectric width (x dimension) | |
7 | +2.1e-3 # parameter 2: dielectric height (y dimension) | |
8 | +1 # parameter 3: number of rows of conductors | |
9 | +0.0e-3 # parameter 4: row 1 centre offset x | |
10 | +0.0e-3 # parameter 5: row 1 centre offset y | |
11 | +1.0e-3 # parameter 6: row 1 conductor width (x dimension) | |
12 | +2e-3 # parameter 7: row 1 conductor height (y dimension) | |
13 | +0.5e-3 # parameter 8: row 1 conductor separation | |
14 | +1 # parameter 9: row 1 number of conductors | |
15 | +0.0 # parameter 10: conductivity | |
16 | +1 # number of frequency dependent parameters | |
17 | +# Dielectric relative permittivity model follows | |
18 | + 1.0000000000000000 # w normalisation constant | |
19 | + 0 # a order, a coefficients follow below: | |
20 | + 1.0000000000000000 | |
21 | + 0 # b order, b coefficients follow below: | |
22 | + 1.0000000000000000 | |
23 | + | |
24 | + | |
25 | + | |
26 | +#MOD_cable_lib_dir | |
27 | +./ | |
28 | +Flex_cable | |
4 | 29 | 1 # number of conductors |
5 | 30 | 6 # number of parameters |
6 | 31 | 1.0000E-03 # parameter 1: conductor width | ... | ... |