ZT_FD_coax2.cable_spec 1.73 KB
#MOD_cable_lib_dir
./
Coax
2                # number of conductors
6                # number of parameters
    4.2000E-04   # parameter 1: inner conductor radius
    2.5000E-03   # parameter 2: shield radius
    2.5000E-03   # parameter 3: outer dielectric radius
    5.0000E+07   # parameter 4: inner wire conductivity
    6.2500E-05   # parameter 5: shield conductor thickness
    5.0000E+07   # parameter 6: shield conductivity
2                # number of frequency dependent parameters
# Inner dielectric relative permittivity model follows
   10000000.000000000        # w normalisation constant
           1   # a order, a coefficients follow below:
   2.6000000000000001        2.3999999999999999     
           1   # b order, b coefficients follow below:
   1.0000000000000000        1.0000000000000000     
# Outer dielectric relative permittivity model follows
   10000000.000000000        # w normalisation constant
           1   # a order, a coefficients follow below:
   2.3999999999999999        2.2000000000000002     
           1   # b order, b coefficients follow below:
   1.0000000000000000        1.0000000000000000     
1                # number of frequency dependent transfer impedance models
# Transfer impedance model follows
   628318530.71795857        # w normalisation constant
           6   # a order, a coefficients follow below:
   2.0374795470322369E-002   7.2958448505304290        173.23440083645696        1070.7212963190307        2662.4483041436774        2973.2386142213127        1443.9703537238854     
           5   # b order, b coefficients follow below:
   1.0000000000000000        23.599449123864325        145.90222072648217        362.78999275303266        405.14016972906620        196.75864271144215     
no_laplace