1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 166 167 168 169 170 171 172 173 174 175 176 177 178 179 180 181 182 183 184 185 186 187 188 189 190 191 192 193 194 195 196 197 198 199 200 201 202 203 204 205 206 207 208 209 210 211 212 213 214 215 216 217 218 219 220 221 222 223 224 225 226 227 228 229 230 231 232 233 234 235 236 237 238 239 240 241 242 243 244 245 246 247 248 249 250 251 252 253 254 255 256 257 258 259 260 261 262 263 264 265 266 267 268 269 270 271 272 273 274 275 276 277 278 279 280 281 282 283 284 285 286 287 288 289 290 291 292 293 294 295 296 297 298 299 300 301 302 303 304 305 306 307 308 309 310 311 312 313 314 315 316 317 318 319 320 321 322 323 324 325 326 327 328 329 330 331 332 333 334 335 336 337 338 339 340 341 342 343 344 345 346 347 348 349 350 351 352 353 354 355 356 357 358 359 360 361 362 363 364 365 366 367 368 369 370 371 372 373 374 375 376 377 378 379 380 381 382 383 384 385 386 387 388 389 390 391 392 393 394 395 396 397 398 399 400 401 402 403 404 405 406 407 408 409 410 411 412 413 414 415 416 417 418 419 420 421 422 423 424 425 426 427 428 429 430 431 432 433 434 435 436 437 438 439 440 441 442 443 444 445 446 447 448 449 450 451 452 453 454 455 456 457 458 459 460 461 462 463 464 465 466 467 468 469 470 471 472 473 474 475 476 477 478 479 480 481 482 483 484 485 486 487 488 489 490 491 492 493 494 495 496 497 498 499 500 501 502 503 504 505 506 507 508 509 510 511 512
!
! This file is part of SACAMOS, State of the Art CAble MOdels in Spice. 
! It was developed by the University of Nottingham and the Netherlands Aerospace 
! Centre (NLR) for ESA under contract number 4000112765/14/NL/HK.
! 
! Copyright (C) 2016-2017 University of Nottingham
! 
! SACAMOS is free software: you can redistribute it and/or modify it under the 
! terms of the GNU General Public License as published by the Free Software 
! Foundation, either version 3 of the License, or (at your option) any later 
! version.
! 
! SACAMOS is distributed in the hope that it will be useful, but 
! WITHOUT ANY WARRANTY; without even the implied warranty of MERCHANTABILITY 
! or FITNESS FOR A PARTICULAR PURPOSE.  See the GNU General Public License 
! for more details.
! 
! A copy of the GNU General Public License version 3 can be found in the 
! file GNU_GPL_v3 in the root or at <http://www.gnu.org/licenses/>.
! 
! SACAMOS uses the EISPACK library (in /SRC/EISPACK). EISPACK is subject to 
! the GNU Lesser General Public License. A copy of the GNU Lesser General Public 
! License version can be found in the file GNU_LGPL in the root of EISPACK 
! (/SRC/EISPACK ) or at <http://www.gnu.org/licenses/>.
! 
! The University of Nottingham can be contacted at: ggiemr@nottingham.ac.uk
!
!
! File Contents:
! PROGRAM cable_model_builder
!
! NAME
!     cable_model_builder
!
! AUTHORS
!     Chris Smartt
!
! DESCRIPTION
!     cable_model_builder collects all the information required to characterise
!     an individual cable from a .cable_spec file. The code performs any calculations necessary to 
!     derive the per-unit-length parameters of any shielded (internal) domains as required. 
!
!     The software supports the following cable types:
!
!     Frequency Dependent Cylindrical conductor with dielectric
!     Frequency Dependent Coaxial cable with transfer impedance and shield surface impedance loss
!     Frequency Dependent Twinax cable with transfer impedance and shield surface impedance loss
!     Frequency Dependent Twisted pair
!     Frequency Dependent Shielded twisted pair with transfer impedance and shield surface impedance loss
!     Frequency Dependent Spacewire with transfer impedance and shield surface impedance loss
!     Frequency Dependent Overshield with transfer impedance and shield surface impedance loss
!     Frequency Dependent flex cable
!     D connector
!
!     The input to the program is the name of a cable specification file. A file name.cable_spec must exist, containing
!     all the data required to specify a cable.
!
!     The output of the cable_model_builder code is a file name.cable which can be used as an input to the 
!     cable_bundle_model_builder software
!
!     The .cable file is placed in a directory specified in the .cable_spec file. This may be the local directory (./) 
!     or another specified path. In this way the software can interact with a library of cable models (MOD).
!
!     The program may be run with the cable name specified in the command line i.e. 'cable_model_builder name'
!     or it the name is absent from the command line, the user is prompted for the name.
!
!
! COMMENTS
!     Updated to V2
!
! HISTORY
!
!     started 25/11/2015 CJS Started STAGE_1 developments 
!     started 21/03/2016 CJS Started STAGE_3 developments 
!     7/4/2016  CJS add twinax, twisted_pair and shielded_twisted_pair cable types
!     27/4/2016 CJS add the conductor impedance (loss) model
!     12/5/2016 CJS Generalise the conductor impedance model to include transfer impedance
!     21/7/2016 CJS add models for FD_twisted_pair ZT_FD_shielded_twisted_pair ZT_FD_spacewire ZT_FD_twinax
!     5/9/2016  CJS Include the shielded cable models with surface impedance loss:
!                   FD_coax2, ZT_FD_coax2, FD_twisted_pair2, ZT_FD_shielded_twisted_pair2, ZT_FD_spacewire2 ZT_FD_twinax2
!     23/9/2016 CJS Include rectangular conductor type
!     16/11/2016 CJS Include Dconnector type
!     December 2016 CJS Version 2: Rationalise cable types so that there is only a single version of each type of cable
!     24/2/2017 CJS Allow the input name to include a path i.e. the _spec file does not need to be local.
!     23/10/2017 CJS Check the pole stability of the dielectric and transfer impedance filters.
!     16/11/2017 CJS Include network synthesis process to replace s-domain transfer functions
!
!
PROGRAM cable_model_builder

USE type_specifications
USE general_module
USE constants
USE cable_module
USE filter_module

IMPLICIT NONE

! local variables

! command line argument value and length
character(len=filename_length)    :: argument1
integer                           :: argument1_length

character(len=filename_length)    :: cable_name_with_path  ! name of the cable including the path
character(len=filename_length)    :: cable_path            ! path to the cable_spec file
character(len=filename_length)    :: cable_name            ! name of the cable
character(len=filename_length)    :: filename              ! filename of the .cable_spec file
    
logical        :: file_exists

! Structure to hold the cable specification (see CABLE_MODULES/cable_module.F90)
type(cable_specification_type)    :: cable_spec

! string for reading flags
character(len=line_length)    :: line

integer        :: ierr   ! integer to return error codes from file reads

! temporary variables for reading number of conductors, parameters, frequency dependent parameters, transfer impedance functions.
integer        :: nc_in,np_in,nFDp_in,nFDZT_in
logical        :: check_passed                   ! flag for stability testing of S domain transfer function filters

! loop variable
integer        :: i

! START

! Open the input file describing the cable parameters
! This file could be created by the associated GUI or otherwise generated

  program_name="cable_model_builder"
  run_status='Started'
  CALL write_program_status()
  
  CALL read_version()
    
  CALL write_license()

! get the first command line argument. If set then this is the cable name, if it is not set then
! it must be read

  CALL get_command_argument(1 , argument1, argument1_length)

  if (argument1_length.NE.0) then
  
    cable_name_with_path =trim(argument1)
  
  else

    write(*,*)'Enter the name of the cable specification data (without .cable_spec extension)'

    read(*,'(A)')cable_name_with_path 

  end if
  
  CALL strip_path(cable_name_with_path,cable_path,cable_name)

  filename=trim(cable_name_with_path)//cable_spec_file_extn

  inquire(file=trim(filename),exist=file_exists)
  if (.NOT.file_exists) then
    run_status='ERROR in cable_model_builder, Cannot find the file:'//trim(filename)
    CALL write_program_status()
    STOP 1
  end if 
  
! open and read the file
  
  OPEN(unit=cable_spec_file_unit,file=filename)

  write(*,*)'Opened file:',trim(filename)
  
! set the cable name to be the same as the name of the cable specification data
  cable_spec%cable_name=cable_name

! set the version tag in the cable structure
  cable_spec%version=SPICE_CABLE_MODEL_BUILDER_version

! read the directory for the cable models
  read(cable_spec_file_unit,*)  ! comment line
  read(cable_spec_file_unit,'(A)')MOD_cable_lib_dir
  CALL path_format(MOD_cable_lib_dir)
  
! ensure that the paths exist
  CALL check_and_make_path(MOD_cable_lib_dir)

! read the cable type
  read(cable_spec_file_unit,'(A)')cable_spec%cable_type_string
  
  CALL convert_to_lower_case(cable_spec%cable_type_string,line_length)
  
  if (cable_spec%cable_type_string.eq.'cylindrical') then

    CALL cylindrical_set_parameters(cable_spec)
    
  else if (cable_spec%cable_type_string.eq.'twisted_pair') then

    CALL twisted_pair_set_parameters(cable_spec)
    
  else if (cable_spec%cable_type_string.eq.'coax') then

    CALL coax_set_parameters(cable_spec)
        
  else if (cable_spec%cable_type_string.eq.'twinax') then

    CALL twinax_set_parameters(cable_spec)
    
  else if (cable_spec%cable_type_string.eq.'shielded_twisted_pair') then

    CALL shielded_twisted_pair_set_parameters(cable_spec)

  else if (cable_spec%cable_type_string.eq.'spacewire') then

    CALL spacewire_set_parameters(cable_spec)

  else if (cable_spec%cable_type_string.eq.'flex_cable') then

    CALL flex_cable_set_parameters(cable_spec)

  else if (cable_spec%cable_type_string.eq.'dconnector') then

    CALL Dconnector_set_parameters(cable_spec)

  else if (cable_spec%cable_type_string.eq.'overshield') then

    CALL overshield_set_parameters(cable_spec)

  else
   
    run_status='ERROR in cable_model_builder, Unknown cable type:'//trim(cable_spec%cable_type_string)
    CALL write_program_status()
    STOP 1
      
  end if

! read the number of conductors from the .cable_spec file 

  read(cable_spec_file_unit,*,IOSTAT=ierr)nc_in
  if (ierr.NE.0) then 
    run_status='ERROR reading number of conductors'
    CALL write_program_status()
    STOP 1
  end if
  
  if (cable_spec%tot_n_conductors.NE.0) then ! This cable type has a specific number of conductors so
! check that the number of conductors is consistent with this cable type

    if (nc_in.NE.cable_spec%tot_n_conductors) then
      run_status='ERROR, Wrong number of conductors'
      CALL write_program_status()
      STOP 1
    end if
    
  else
! the number of conductors is set in the cable specification so set the 
! paramter values accordingly

    cable_spec%tot_n_conductors=nc_in
    
! if the number of external conductors is not set then we assume that all condcutors are external (e.g. flex cable)
    if (cable_spec%n_external_conductors.NE.0) then
      cable_spec%n_external_conductors=nc_in
    end if
    
  end if
  
! read the number of parameters from the .cable_spec file 

  read(cable_spec_file_unit,*,IOSTAT=ierr)np_in
  if (ierr.NE.0) then 
    run_status='ERROR reading number of parameters'
    CALL write_program_status()
    STOP 1
  end if
  
! Check that the number of parameters is consistent with this cable type
  if (np_in.NE.cable_spec%n_parameters) then
    run_status='ERROR, Wrong number of parameters'
    CALL write_program_status()
    STOP 1
  end if

! allocate and read parameters

  ALLOCATE( cable_spec%parameters(1:cable_spec%n_parameters) )
  
  do i=1,cable_spec%n_parameters

    read(cable_spec_file_unit,*,IOSTAT=ierr)cable_spec%parameters(i)
    if (ierr.NE.0) then 
      run_status='ERROR reading cable_spec%parameters'
      CALL write_program_status()
      STOP 1
    end if
  
  end do

! read the number of dielectric filters from the .cable_spec file or assume 0 if the information is not there

  read(cable_spec_file_unit,*,IOSTAT=ierr)nFDp_in
  if (ierr.NE.0) then 
! Assume that there are no frequency dependent dielectric models
    backspace(cable_spec_file_unit)
    nFDp_in=0
  end if
  
! Check that the number of dielectric filters is consistent with this cable type
  if (nFDp_in.NE.cable_spec%n_dielectric_filters) then
    run_status='ERROR, Wrong number of dielectric models for this cable type'
    CALL write_program_status()
    STOP 1
  end if
  
  if (cable_spec%n_dielectric_filters.GT.0) then
    ALLOCATE( cable_spec%dielectric_filter(1:cable_spec%n_dielectric_filters) )
    do i=1,cable_spec%n_dielectric_filters
      read(cable_spec_file_unit,*,IOSTAT=ierr)    ! comment line
      CALL read_Sfilter(cable_spec%dielectric_filter(i),cable_spec_file_unit)
      
! test pole stability
      CALL test_filter_pole_stability(cable_spec%dielectric_filter(i),check_passed)
  
      if (.NOT.check_passed) then
        write(*,*)'ERROR in cable_model_builder'
        write(*,*)'The dielectric filter function has unstable poles'
        write(*,*)'Dielectric filter function number:',i
        CALL write_Sfilter(cable_spec%dielectric_filter(i),0)
        write(run_status,'(A,I2)')'ERROR, Unstable poles in dielectric filter function: ',i
        CALL write_program_status()
        STOP 1
      else
        if (verbose) write(*,*)'The dielectric filter function has stable poles: function number ',i    
      end if
          
    end do
  end if
   
! read the number of transfer impedance filters from the .cable_spec file or assume 0 if the information is not there

  read(cable_spec_file_unit,*,IOSTAT=ierr)nFDZT_in
  if (ierr.NE.0) then 
! Assume that there are no transfer impedance filters
    backspace(cable_spec_file_unit)
    nFDZT_in=0
  end if
  
! Check that the number of transfer impedance filters is consistent with this cable type
  if (nFDZT_in.NE.cable_spec%n_transfer_impedance_models) then
    run_status='ERROR, Wrong number of transfer impedance models for this cable type'
    CALL write_program_status()
    STOP 1
  end if
  
  if (cable_spec%n_transfer_impedance_models.GT.0) then
    ALLOCATE( cable_spec%transfer_impedance(1:cable_spec%n_transfer_impedance_models) )
    do i=1,cable_spec%n_transfer_impedance_models
      read(cable_spec_file_unit,*,IOSTAT=ierr)    ! comment line
      CALL read_Sfilter(cable_spec%transfer_impedance(i),cable_spec_file_unit)
      
! test pole stability
      CALL test_filter_pole_stability(cable_spec%transfer_impedance(i),check_passed)
  
      if (.NOT.check_passed) then
        write(*,*)'ERROR in cable_rmpedance filter function has unstable poles'
        write(*,*)'Transfer impedance filter function number:',i
        CALL write_Sfilter(cable_spec%transfer_impedance(i),0)
        write(run_status,'(A,I2)')'ERROR, Unstable poles in transfer impedance filter function: ',i
        CALL write_program_status()
        STOP 1
      else
        if (verbose) write(*,*)'The transfer impedance filter function has stable poles: function number ',i    
      end if
    end do
  end if
   
! Set deafult propagation correction transfer function fit information
  cable_spec%Y_fit_model_order=0  
  CALL reset_frequency_specification(cable_spec%Y_fit_freq_spec)
  CALL set_up_frequency_specification(cable_spec%Y_fit_freq_spec)
  
! Read the optional propagation correction transfer function fit information
  read(cable_spec_file_unit,*,IOSTAT=ierr)cable_spec%Y_fit_model_order
  if (ierr.NE.0) then
! Assume there is no filter fit information specified so move on to the next stage
    backspace(cable_spec_file_unit)
    goto 100
  end if
  
  write(*,*)'Reading the filter fit frequency range'
  
  CALL read_and_set_up_frequency_specification(cable_spec%Y_fit_freq_spec,cable_spec_file_unit)

100 continue
  
! the end of the file can contain flags to control the running of the software and the output

  do
    read(cable_spec_file_unit,*,END=110,ERR=110)line
    CALL convert_to_lower_case(line,line_length)

! Set flags according to the information at the end of the .spice_model_spec file
  
    if (INDEX(line,'verbose').NE.0) verbose=.TRUE.
    if (INDEX(line,'use_s_xfer').NE.0) use_s_xfer=.TRUE.
    if (INDEX(line,'no_s_xfer').NE.0) use_s_xfer=.FALSE.
    if (INDEX(line,'use_laplace').NE.0) use_Laplace=.TRUE.
    if (INDEX(line,'no_laplace').NE.0) use_Laplace=.FALSE.
    if (INDEX(line,'plot_potential').NE.0) plot_potential=.TRUE.
    if (INDEX(line,'no_plot_potential').NE.0) plot_potential=.FALSE.
    if (INDEX(line,'plot_mesh').NE.0) plot_mesh=.TRUE.
    if (INDEX(line,'no_plot_mesh').NE.0) plot_mesh=.FALSE.

! redefine mesh generation parameters if required
    if (INDEX(line,'laplace_boundary_constant').NE.0) then
      read(cable_spec_file_unit,*,END=100,ERR=100)Laplace_boundary_constant
    end if
    
    if (INDEX(line,'laplace_surface_mesh_constant').NE.0) then
      read(cable_spec_file_unit,*,END=100,ERR=100)Laplace_surface_mesh_constant
    end if
    
    if (INDEX(line,'twisted_pair_equivalent_radius').NE.0) then
      read(cable_spec_file_unit,*,END=100,ERR=100)Twisted_pair_equivalent_radius
    end if

  end do  ! continue until all flags are read - indicated by an end of file.

110 CONTINUE
  
! close the file with the cable data
  CLOSE(unit=cable_spec_file_unit)
  
  if (cable_spec%n_internal_domains.GT.0) then
! construct the information for the internal domains

! allocate internal domain information
    ALLOCATE(cable_spec%n_internal_conductors_in_domain(1:cable_spec%n_internal_domains))
    ALLOCATE(cable_spec%L_domain(1:cable_spec%n_internal_domains))
    ALLOCATE(cable_spec%C_domain(1:cable_spec%n_internal_domains))
    ALLOCATE(cable_spec%Z_domain(1:cable_spec%n_internal_domains))
    ALLOCATE(cable_spec%Y_domain(1:cable_spec%n_internal_domains))

  end if ! There are internal domains requiring parameter specification

! allocate the conductor based impedance model and reset all parameters assuming PEC for now
  ALLOCATE( cable_spec%conductor_impedance(1:cable_spec%tot_n_conductors) )
  do i=1,cable_spec%tot_n_conductors
    cable_spec%conductor_impedance(i)%impedance_model_type=impedance_model_type_PEC
    cable_spec%conductor_impedance(i)%radius=0d0
    cable_spec%conductor_impedance(i)%conductivity=0d0
    cable_spec%conductor_impedance(i)%Resistance_multiplication_factor=1d0
  end do
      
! Set the cable structure information according to each cable type
  
  if (cable_spec%cable_type.EQ.cable_geometry_type_cylindrical) then

    CALL cylindrical_set_internal_domain_information(cable_spec)
  
  else if (cable_spec%cable_type.EQ.cable_geometry_type_twisted_pair) then

    CALL twisted_pair_set_internal_domain_information(cable_spec)

  else if (cable_spec%cable_type.EQ.cable_geometry_type_coax) then

    CALL coax_set_internal_domain_information(cable_spec)

  else if (cable_spec%cable_type.EQ.cable_geometry_type_twinax) then

    CALL twinax_set_internal_domain_information(cable_spec)

  else if (cable_spec%cable_type.EQ.cable_geometry_type_shielded_twisted_pair) then

    CALL shielded_twisted_pair_set_internal_domain_information(cable_spec)
    
  else if (cable_spec%cable_type.EQ.cable_geometry_type_spacewire) then

    CALL spacewire_set_internal_domain_information(cable_spec)

  else if (cable_spec%cable_type.EQ.cable_geometry_type_flex_cable) then

    CALL flex_cable_set_internal_domain_information(cable_spec)

  else if (cable_spec%cable_type.EQ.cable_geometry_type_dconnector) then

    CALL dconnector_set_internal_domain_information(cable_spec)
  
  else if (cable_spec%cable_type.EQ.cable_geometry_type_overshield) then

    CALL overshield_set_internal_domain_information(cable_spec)
  
  end if

! Write the cable information to a .cable file

  CAll write_cable(cable_spec,cable_file_unit)

! deallocate memory used
  
  CALL deallocate_frequency_specification(cable_spec%Y_fit_freq_spec)

  CAll deallocate_cable(cable_spec)

! finish up

  run_status='Finished_Correctly'
  CALL write_program_status()
  
END PROGRAM cable_model_builder