edge_coupled_stripline.cable_spec
1.59 KB
#MOD_cable_lib_dir
.
flex_cable
4 # number of conductors
22 # number of parameters
3.5e-3 # parameter 1: dielectric width (x dimension)
0.55e-3 # parameter 2: dielectric height (y dimension)
3 # parameter 3: number of rows of conductors
0.0e-3 # parameter 4: row 1 centre offset x
0.0e-3 # parameter 5: row 1 centre offset y
0.25e-3 # parameter 6: row 1 conductor width (x dimension)
0.01e-3 # parameter 7: row 1 conductor height (y dimension)
0.25e-3 # parameter 8: row 1 conductor separation
2 # parameter 9: row 1 number of conductors
0.0e-3 # parameter 10: row 2 centre offset x
0.245e-3 # parameter 11: row 2 centre offset y
3.00e-3 # parameter 12: row 2 conductor width (x dimension)
0.03e-3 # parameter 13: row 2 conductor height (y dimension)
0.25e-3 # parameter 14: row 2 conductor separation
1 # parameter 15: row 2 number of conductors
0.0e-3 # parameter 16: row 3 centre offset x
-0.245e-3 # parameter 17: row 3 centre offset y
3.00e-3 # parameter 18: row 3 conductor width (x dimension)
0.03e-3 # parameter 19: row 3 conductor height (y dimension)
0.25e-3 # parameter 20: row 3 conductor separation
1 # parameter 21: row 3 number of conductors
0.0 # parameter 22: conductivity
1 # number of frequency dependent parameters
# dielectric relative permittivity model follows
1E9 # w normalisation constant
0 # a order, a coefficients follow below:
3.4
0 # b order, b coefficients follow below:
1.0