create_global_domain_structure.F90 66.7 KB
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 166 167 168 169 170 171 172 173 174 175 176 177 178 179 180 181 182 183 184 185 186 187 188 189 190 191 192 193 194 195 196 197 198 199 200 201 202 203 204 205 206 207 208 209 210 211 212 213 214 215 216 217 218 219 220 221 222 223 224 225 226 227 228 229 230 231 232 233 234 235 236 237 238 239 240 241 242 243 244 245 246 247 248 249 250 251 252 253 254 255 256 257 258 259 260 261 262 263 264 265 266 267 268 269 270 271 272 273 274 275 276 277 278 279 280 281 282 283 284 285 286 287 288 289 290 291 292 293 294 295 296 297 298 299 300 301 302 303 304 305 306 307 308 309 310 311 312 313 314 315 316 317 318 319 320 321 322 323 324 325 326 327 328 329 330 331 332 333 334 335 336 337 338 339 340 341 342 343 344 345 346 347 348 349 350 351 352 353 354 355 356 357 358 359 360 361 362 363 364 365 366 367 368 369 370 371 372 373 374 375 376 377 378 379 380 381 382 383 384 385 386 387 388 389 390 391 392 393 394 395 396 397 398 399 400 401 402 403 404 405 406 407 408 409 410 411 412 413 414 415 416 417 418 419 420 421 422 423 424 425 426 427 428 429 430 431 432 433 434 435 436 437 438 439 440 441 442 443 444 445 446 447 448 449 450 451 452 453 454 455 456 457 458 459 460 461 462 463 464 465 466 467 468 469 470 471 472 473 474 475 476 477 478 479 480 481 482 483 484 485 486 487 488 489 490 491 492 493 494 495 496 497 498 499 500 501 502 503 504 505 506 507 508 509 510 511 512 513 514 515 516 517 518 519 520 521 522 523 524 525 526 527 528 529 530 531 532 533 534 535 536 537 538 539 540 541 542 543 544 545 546 547 548 549 550 551 552 553 554 555 556 557 558 559 560 561 562 563 564 565 566 567 568 569 570 571 572 573 574 575 576 577 578 579 580 581 582 583 584 585 586 587 588 589 590 591 592 593 594 595 596 597 598 599 600 601 602 603 604 605 606 607 608 609 610 611 612 613 614 615 616 617 618 619 620 621 622 623 624 625 626 627 628 629 630 631 632 633 634 635 636 637 638 639 640 641 642 643 644 645 646 647 648 649 650 651 652 653 654 655 656 657 658 659 660 661 662 663 664 665 666 667 668 669 670 671 672 673 674 675 676 677 678 679 680 681 682 683 684 685 686 687 688 689 690 691 692 693 694 695 696 697 698 699 700 701 702 703 704 705 706 707 708 709 710 711 712 713 714 715 716 717 718 719 720 721 722 723 724 725 726 727 728 729 730 731 732 733 734 735 736 737 738 739 740 741 742 743 744 745 746 747 748 749 750 751 752 753 754 755 756 757 758 759 760 761 762 763 764 765 766 767 768 769 770 771 772 773 774 775 776 777 778 779 780 781 782 783 784 785 786 787 788 789 790 791 792 793 794 795 796 797 798 799 800 801 802 803 804 805 806 807 808 809 810 811 812 813 814 815 816 817 818 819 820 821 822 823 824 825 826 827 828 829 830 831 832 833 834 835 836 837 838 839 840 841 842 843 844 845 846 847 848 849 850 851 852 853 854 855 856 857 858 859 860 861 862 863 864 865 866 867 868 869 870 871 872 873 874 875 876 877 878 879 880 881 882 883 884 885 886 887 888 889 890 891 892 893 894 895 896 897 898 899 900 901 902 903 904 905 906 907 908 909 910 911 912 913 914 915 916 917 918 919 920 921 922 923 924 925 926 927 928 929 930 931 932 933 934 935 936 937 938 939 940 941 942 943 944 945 946 947 948 949 950 951 952 953 954 955 956 957 958 959 960 961 962 963 964 965 966 967 968 969 970 971 972 973 974 975 976 977 978 979 980 981 982 983 984 985 986 987 988 989 990 991 992 993 994 995 996 997 998 999 1000 1001 1002 1003 1004 1005 1006 1007 1008 1009 1010 1011 1012 1013 1014 1015 1016 1017 1018 1019 1020 1021 1022 1023 1024 1025 1026 1027 1028 1029 1030 1031 1032 1033 1034 1035 1036 1037 1038 1039 1040 1041 1042 1043 1044 1045 1046 1047 1048 1049 1050 1051 1052 1053 1054 1055 1056 1057 1058 1059 1060 1061 1062 1063 1064 1065 1066 1067 1068 1069 1070 1071 1072 1073 1074 1075 1076 1077 1078 1079 1080 1081 1082 1083 1084 1085 1086 1087 1088 1089 1090 1091 1092 1093 1094 1095 1096 1097 1098 1099 1100 1101 1102 1103 1104 1105 1106 1107 1108 1109 1110 1111 1112 1113 1114 1115 1116 1117 1118 1119 1120 1121 1122 1123 1124 1125 1126 1127 1128 1129 1130 1131 1132 1133 1134 1135 1136 1137 1138 1139 1140 1141 1142 1143 1144 1145 1146 1147 1148 1149 1150 1151 1152 1153 1154 1155 1156 1157 1158 1159 1160 1161 1162 1163 1164 1165 1166 1167 1168 1169 1170 1171 1172 1173 1174 1175 1176 1177 1178 1179 1180 1181 1182 1183 1184 1185 1186 1187 1188 1189 1190 1191 1192 1193 1194 1195 1196 1197 1198 1199 1200 1201 1202 1203 1204 1205 1206 1207 1208 1209 1210 1211 1212 1213 1214 1215 1216 1217 1218 1219 1220 1221 1222 1223 1224 1225 1226 1227 1228 1229 1230 1231 1232 1233 1234 1235 1236 1237 1238 1239 1240 1241 1242 1243 1244 1245 1246 1247 1248 1249 1250 1251 1252 1253 1254 1255 1256 1257 1258 1259 1260 1261 1262 1263 1264 1265 1266 1267 1268 1269 1270 1271 1272 1273 1274 1275 1276 1277 1278 1279 1280 1281 1282 1283 1284 1285 1286 1287 1288 1289 1290 1291 1292 1293 1294 1295 1296 1297 1298 1299 1300 1301 1302 1303 1304 1305 1306 1307 1308 1309 1310 1311 1312 1313 1314 1315 1316 1317 1318 1319 1320 1321 1322 1323 1324 1325 1326 1327 1328 1329 1330 1331 1332 1333 1334 1335 1336 1337 1338 1339 1340 1341 1342 1343 1344 1345 1346 1347 1348 1349 1350 1351 1352 1353 1354 1355 1356 1357 1358 1359 1360 1361 1362 1363 1364 1365 1366 1367 1368 1369 1370 1371 1372 1373 1374 1375 1376 1377 1378 1379 1380 1381 1382 1383 1384 1385 1386 1387 1388 1389 1390 1391 1392 1393 1394 1395 1396 1397 1398 1399 1400 1401 1402 1403 1404 1405 1406 1407 1408 1409 1410 1411 1412 1413 1414 1415 1416 1417 1418 1419 1420 1421 1422 1423 1424 1425 1426 1427 1428 1429 1430 1431 1432 1433 1434 1435 1436 1437 1438 1439 1440 1441 1442 1443 1444 1445 1446 1447 1448 1449 1450 1451 1452 1453 1454 1455 1456 1457 1458 1459 1460 1461 1462 1463 1464 1465 1466 1467 1468 1469 1470 1471 1472 1473 1474 1475 1476 1477 1478 1479 1480 1481 1482 1483 1484 1485 1486 1487 1488 1489 1490 1491 1492 1493 1494 1495 1496 1497 1498 1499 1500 1501 1502 1503 1504 1505 1506 1507 1508 1509 1510 1511 1512 1513 1514 1515 1516 1517 1518 1519 1520 1521 1522 1523 1524 1525 1526 1527 1528 1529 1530 1531 1532 1533 1534 1535 1536 1537 1538 1539 1540 1541 1542 1543 1544 1545 1546 1547 1548 1549 1550 1551 1552 1553 1554 1555 1556 1557 1558 1559 1560 1561 1562 1563 1564 1565 1566 1567 1568 1569 1570 1571 1572 1573 1574
!
! This file is part of SACAMOS, State of the Art CAble MOdels for Spice. 
! It was developed by the University of Nottingham and the Netherlands Aerospace 
! Centre (NLR) for ESA under contract number 4000112765/14/NL/HK.
! 
! Copyright (C) 2016-2018 University of Nottingham
! 
! SACAMOS is free software: you can redistribute it and/or modify it under the 
! terms of the GNU General Public License as published by the Free Software 
! Foundation, either version 3 of the License, or (at your option) any later 
! version.
! 
! SACAMOS is distributed in the hope that it will be useful, but 
! WITHOUT ANY WARRANTY; without even the implied warranty of MERCHANTABILITY 
! or FITNESS FOR A PARTICULAR PURPOSE.  See the GNU General Public License 
! for more details.
! 
! A copy of the GNU General Public License version 3 can be found in the 
! file GNU_GPL_v3 in the root or at <http://www.gnu.org/licenses/>.
! 
! SACAMOS uses the EISPACK library (in /SRC/EISPACK). EISPACK is subject to 
! the GNU Lesser General Public License. A copy of the GNU Lesser General Public 
! License version can be found in the file GNU_LGPL in the root of EISPACK 
! (/SRC/EISPACK ) or at <http://www.gnu.org/licenses/>.
! 
! The University of Nottingham can be contacted at: ggiemr@nottingham.ac.uk
!
!
! NAME
!     SUBROUTINE create_global_domain_structure
!
! DESCRIPTION
!   The processes implemented in this subroutine calculate the matrices which are required to 
!   characterise the multi-conductor cable propagation in both a local, domain based system for the Spice model development
!   and in a global basis for analysis of the bundle as a whole for the validation test circuit.
!   The matrices characterising the propagation are :
!       the domain based 'high frequency' L and C matrices,
!       the domain based frequency dependent Z and Y matrices,
!       the global  'high frequency' L and C matrices,
!       the global frequency dependent Z and Y matrices,
!       the voltage and current domain decomposition matrices MI and MV
!
!   For shielded domains the L, C, Z, and Y matrices are known from the cable data structures
!   For any overshield domains and the external domain these matrices are calculated here via
!   calls to the appopriate PUL calculation subroutines
!
!   The processes implemented in this subroutine are summarised as follows:
!
! 1. Count the total number of conductors in the bundle and Allocate and reset the local data structures 
! 2. Loop over the cables filling the referencing arrays with local information
! 3. For each cable, work out which domain it is in and hence its reference conductor number.
! 4. Count the number of conductors in the external domain to check whether it is viable i.e. at least 2 conductors
! 5. build the global_domain numbering, ignoring any unused domains
! 6. build the domain based L and C matrices plus the global MI and MV matrices and the global L and C matrices
! 7. Calculate the inductance and capacitance matrices for the external domains (domains within overshields and the external domain)
! 8. Copy the cable based conductor impedance (loss) models to the bundle structure
! 8b. Copy the cable based conductor labels to the bundle structure
! 9  save numbering information required for the transfer impedance calculation
! 10. deallocate local memory
!     
! COMMENTS
!     
!
! HISTORY
!    started 2/12/2015 CJS
!     27/4/2016 CJS: Include a conductor based impedance (loss) model
!     24/5/2016 CJS: Fix errors in MI and MV matrices for multi-conductor overshield domains
!     7/7/2016 CJS: Allow the use of the Laplace solver for L,C,G matrix calculation in external and overshield domains.
!     9/9/2016 CJS: Fix problem with MV and MI matrix for the twisted pair model. Elements were being overwritten incorrectly.
!                   when adding the external conductor contribution to the domain decomposition matrices   
!     4/10/2016 CJS: Save the local domain conductor numbering
!     17/5/2017 CJS: Work out which domains are Shielded Twisted Pair differential mode domains and flag these
!                    so that we can work out the is_shield flag properly in all circumstances.
!     18/10/2017 CJS: include 8b. Copy the cable based conductor labels to the bundle structure
!     16/11/2017 CJS Include network synthesis process to replace s-domain transfer functions
!     16/3/2018 CJS  add y offset for ML_flex_cable
!     22/10/2019 CJS Fix bug with numbering here: overshields were numbered using terminal conductor number not global domain number
!     24/10/2019 CJS Allow mutliple layers of overshields (previously overshields could not be 'nested' 
!                    (though they could cover shielded cables).
!

SUBROUTINE create_global_domain_structure(bundle)

USE type_specifications
USE general_module
USE constants
USE cable_module
USE cable_bundle_module
USE PUL_parameter_module
USE filter_module
USE maths

  IMPLICIT NONE

! variables passed to subroutine

  type(bundle_specification_type),intent(INOUT)    :: bundle
  
! local variables

! global cable, conductor and domain numbers and loop variables
  integer :: cable,cable_t
  integer :: tot_n_cables  
  integer :: tot_n_cables_without_ground_plane
  
  integer :: tot_n_conductors,conductor,conductor_count,terminal_conductor
  integer :: tot_n_domains,tot_n_viable_domains,domain,domain_count
  integer :: tot_n_internal_domains

! local conductor and domain numbers and loop variables

  integer :: local_n_conductors,local_conductor,n_cable_conductors
  integer :: local_cable_conductor,local_domain_conductor
  integer :: local_n_domains,local_domain
  integer :: first_external_domain
  integer :: reference_conductor,global_reference_conductor
  integer :: first_external_conductor
  
! variables for looking at overshields and determining which domain cables are in
  integer :: tot_n_overshields,n_overshield_domains,overshield,reference_overshield
  real(dp)::radius_reference_overshield
  
  integer,allocatable  :: overshield_shape(:)
  real(dp),allocatable :: overshield_x(:)
  real(dp),allocatable :: overshield_y(:)
  real(dp),allocatable :: overshield_r(:)
  real(dp),allocatable :: overshield_w(:)
  real(dp),allocatable :: overshield_w2(:)
  real(dp),allocatable :: overshield_h(:)
  integer,allocatable  :: overshield_domain(:)
  integer,allocatable  :: overshield_reference_terminal_conductor(:)
  integer,allocatable  :: overshield_to_cable_number(:)

  integer,allocatable  :: overshield_n_conductors(:)
  integer,allocatable  :: overshield_terminal_conductor(:,:) 
  
  real(dp) :: cable_x,cable_y,dist_cable_to_overshield_centre,cable_r
  logical :: is_overshield_domain

! referencing arrays
  integer,allocatable :: terminal_conductor_to_cable(:)  
  integer,allocatable :: terminal_conductor_to_cable_local_domain(:)  
  integer,allocatable :: terminal_conductor_to_global_domain(:)  
  integer,allocatable :: terminal_conductor_to_global_domain_conductor(:)  
  integer,allocatable :: terminal_conductor_to_reference_global_domain_conductor(:)  
  integer,allocatable :: terminal_conductor_to_reference_terminal_conductor(:)  
  integer,allocatable :: global_domain_conductor_to_terminal_conductor(:)  
  
  logical,allocatable :: terminal_conductor_is_reference_conductor(:)  
  logical,allocatable :: domain_is_TP_differential_mode(:)  

  integer,allocatable :: cable_reference_domain(:) 
  integer,allocatable :: cable_reference_conductor(:) 
  
  integer,allocatable :: external_terminal_conductor(:)
  logical :: is_external_domain
  integer :: external_conductor_count
  
  integer,allocatable :: global_domain_reference_conductor(:)

! structure used by the Per-Unit-Length parameter calculation for overshield and external domains
  type(PUL_type)    :: PUL

! loop variables for matrix operations
  integer :: dim
  integer :: row,col
  integer :: row_l,col_l
  integer :: row_g,col_g,row_g_ref
  
  character(LEN=3) :: conductor_string  ! used to generate the conductor labels in the bundle
     
! START

  if(verbose) write(*,*)'CALLED: create_global_domain_structure'
  
! Copy some data to local variables for clarity of notation

  tot_n_cables=bundle%n_cables
  
  if (bundle%ground_plane_present) then
    tot_n_cables_without_ground_plane=tot_n_cables-1
  else
    tot_n_cables_without_ground_plane=tot_n_cables
  end if
  
  if(verbose) write(*,*)' Total number of cables=',tot_n_cables
  if(verbose) write(*,*)' Total number of cables not including ground plane=',tot_n_cables_without_ground_plane
  
! 1a. Count the total number of conductors in the bundle

  tot_n_conductors=0
  do cable=1,tot_n_cables  
    tot_n_conductors = tot_n_conductors + bundle%cable(cable)%tot_n_conductors                   
  end do
  
  if(verbose) write(*,*)' Total number of conductors=',tot_n_conductors
  
  bundle%tot_n_conductors=tot_n_conductors
  bundle%system_dimension=tot_n_conductors-1
  
! 1b Allocate and reset the local data structures 

  ALLOCATE( terminal_conductor_to_cable(1:tot_n_conductors) )
  ALLOCATE( terminal_conductor_to_cable_local_domain(1:tot_n_conductors) )
  ALLOCATE( terminal_conductor_to_global_domain(1:tot_n_conductors) )
  ALLOCATE( terminal_conductor_to_global_domain_conductor(1:tot_n_conductors) )
  ALLOCATE( terminal_conductor_to_reference_global_domain_conductor(1:tot_n_conductors) )
  ALLOCATE( terminal_conductor_to_reference_terminal_conductor(1:tot_n_conductors) )
  ALLOCATE( terminal_conductor_is_reference_conductor(1:tot_n_conductors) )
  ALLOCATE( global_domain_conductor_to_terminal_conductor(1:tot_n_conductors) )
  terminal_conductor_to_cable(1:tot_n_conductors)=0
  terminal_conductor_to_cable_local_domain(1:tot_n_conductors)=0
  terminal_conductor_to_global_domain(1:tot_n_conductors)=0
  terminal_conductor_to_global_domain_conductor(1:tot_n_conductors)=0
  terminal_conductor_to_reference_global_domain_conductor(1:tot_n_conductors)=0
  terminal_conductor_to_reference_terminal_conductor(1:tot_n_conductors)=0
  terminal_conductor_is_reference_conductor(1:tot_n_conductors)=.FALSE.
  global_domain_conductor_to_terminal_conductor(1:tot_n_conductors)=0
   
! numbering information required for the transfer impedance calculation
  ALLOCATE( bundle%terminal_conductor_is_shield_flag(1:bundle%tot_n_conductors) )
  ALLOCATE( bundle%terminal_conductor_to_inner_domain(1:bundle%tot_n_conductors) )
  ALLOCATE( bundle%terminal_conductor_to_outer_domain(1:bundle%tot_n_conductors) )
  ALLOCATE( bundle%terminal_conductor_to_global_domain_conductor(1:bundle%tot_n_conductors) )
  ALLOCATE( bundle%terminal_conductor_to_local_domain_conductor(1:bundle%tot_n_conductors) )
  ALLOCATE( bundle%terminal_conductor_to_reference_terminal_conductor(1:bundle%tot_n_conductors) )
  bundle%terminal_conductor_is_shield_flag(1:bundle%tot_n_conductors)=.FALSE.
  bundle%terminal_conductor_to_inner_domain(1:bundle%tot_n_conductors)=0
  bundle%terminal_conductor_to_outer_domain(1:bundle%tot_n_conductors)=0
  bundle%terminal_conductor_to_global_domain_conductor(1:bundle%tot_n_conductors)=0
  bundle%terminal_conductor_to_local_domain_conductor(1:bundle%tot_n_conductors)=0
  bundle%terminal_conductor_to_reference_terminal_conductor(1:bundle%tot_n_conductors)=0
  
! 2. Loop over the cables filling the referencing arrays with local information
! Also count the total number of internal domains in the bundle
  conductor=0
  tot_n_domains=0
  
  do cable=1,tot_n_cables
  
    local_n_domains=bundle%cable(cable)%tot_n_domains
    tot_n_domains=tot_n_domains+bundle%cable(cable)%n_internal_domains
    
    do local_domain=1,local_n_domains
    
      local_n_conductors=bundle%cable(cable)%local_domain_n_conductors(local_domain)-1 ! subtract 1 as the reference conductor is included
      
      do local_conductor=1,local_n_conductors
    
        conductor=conductor+1
        terminal_conductor_to_cable(conductor)=cable
        terminal_conductor_to_cable_local_domain(conductor)=local_domain
        
      end do
      
    end do ! next conductor in this cable
    
  end do
  
  tot_n_internal_domains=tot_n_domains
  first_external_domain=tot_n_domains+1
  
  if(verbose) then
    write(*,*)'Total number of internal domains=',tot_n_domains
    write(*,*)'First external domain=',first_external_domain
  end if
  
! check counting...
  if (conductor.NE.tot_n_conductors) then
    run_status='ERROR in create_global_domain_structure: last conductor.NE.tot_n_conductors'
    CALL write_program_status()
    STOP 1
  end if

! 3. For each cable, work out which domain it is in and hence its reference conductor number.

! 3a. first count the overshields

  tot_n_overshields=0
  do cable=1,tot_n_cables
    if (bundle%cable(cable)%cable_type.EQ.cable_geometry_type_overshield) then 
      tot_n_overshields=tot_n_overshields+1
    end if
  end do
  
  if(verbose) write(*,*)'Total number of over-shields=',tot_n_overshields  

! 3b. Get the position of the overshields
  if (tot_n_overshields.GT.0) then
  
    ALLOCATE( overshield_shape(1:tot_n_overshields)  )
    ALLOCATE( overshield_x(1:tot_n_overshields)  )
    ALLOCATE( overshield_y(1:tot_n_overshields)  )
    ALLOCATE( overshield_r(1:tot_n_overshields)  )
    ALLOCATE( overshield_w(1:tot_n_overshields)  )
    ALLOCATE( overshield_w2(1:tot_n_overshields)  )
    ALLOCATE( overshield_h(1:tot_n_overshields)  )
    ALLOCATE( overshield_reference_terminal_conductor(1:tot_n_overshields) )
    ALLOCATE( overshield_to_cable_number(1:tot_n_overshields) )
    
    overshield=0
    conductor_count=0
    do cable=1,tot_n_cables
      if (bundle%cable(cable)%cable_type.EQ.cable_geometry_type_overshield) then 
        overshield=overshield+1
        overshield_to_cable_number(overshield)=cable
        overshield_shape(overshield)=circle
        overshield_x(overshield)=bundle%cable_x_offset(cable)
        overshield_y(overshield)=bundle%cable_y_offset(cable)
        overshield_r(overshield)=bundle%cable(cable)%parameters(1)  ! overshield radius
        overshield_w(overshield)=0d0
        overshield_w2(overshield)=0d0
        overshield_h(overshield)=0d0
        overshield_reference_terminal_conductor(overshield)=conductor_count+1
        
      else

! This is not an overshield

        if ( (bundle%cable(cable)%cable_type.NE.cable_geometry_type_ground_plane) .AND. (overshield.NE.0) ) then

! check that oveshields are the last conductors defined in the bundle_spec file
          run_status='ERROR, Overshields should be the last cables defined in the bundle specification'
          CALL write_program_status()
          STOP 1
        
        end if      
      
      end if
      conductor_count=conductor_count+bundle%cable(cable)%tot_n_conductors
    end do
    
    ALLOCATE( overshield_domain(1:tot_n_overshields)  )
    overshield_domain(1:tot_n_overshields)=0
    ALLOCATE( overshield_n_conductors(1:tot_n_overshields)  )
    overshield_n_conductors(1:tot_n_overshields)=0
    ALLOCATE( overshield_terminal_conductor(1:tot_n_overshields,1:tot_n_conductors)  ) ! over the top memory allocation here but simpler this way
    overshield_terminal_conductor(1:tot_n_overshields,1:tot_n_conductors)=0
    
  end if  ! n_overshields.GT.0

! allocate array for domain reference conductors assuming worst case that all overshields and external domain are viable  
  ALLOCATE( global_domain_reference_conductor(1:tot_n_domains+tot_n_overshields+1) )
  global_domain_reference_conductor(1:tot_n_domains+tot_n_overshields+1)=0
  
! 3c. Loop over cables and see whether it sits within an overshield or not  
  
  ALLOCATE( cable_reference_domain(1:bundle%n_cables)  )
  cable_reference_domain(1:bundle%n_cables)=0
  ALLOCATE( cable_reference_conductor(1:bundle%n_cables)  )
  cable_reference_conductor(1:bundle%n_cables)=0
  n_overshield_domains=0     ! counter for overshield domains
  
  write(*,*)'**********************************************************************'
  
  do cable=1,tot_n_cables
  
    write(*,*)
    write(*,*)'Checking cable number',cable
  
    if (bundle%cable(cable)%cable_type.NE.cable_geometry_type_overshield) then 
    
! IF THIS CABLE IS NOT AN OVERSHIELD THEN SEE WHETHER IT IS WITHIN AN OVERSHIELD
  
      write(*,*)'THIS CABLE IS NOT AN OVERSHIELD'

      cable_x=bundle%cable_x_offset(cable)
      cable_y=bundle%cable_y_offset(cable)

! find the smallest overshield enclosing this cable      

      reference_overshield=0
      radius_reference_overshield=1d30
      
      do overshield=1,tot_n_overshields
            
        dist_cable_to_overshield_centre=sqrt( (cable_x-overshield_x(overshield))**2+  &
                                                (cable_y-overshield_y(overshield))**2  )
                                              
        if ( dist_cable_to_overshield_centre.LT.overshield_r(overshield) ) then
! we conclude that this cable is within the overshield

          write(*,*)'This cable is inside overshield number',overshield

          if (radius_reference_overshield.GT.overshield_r(overshield)) then
! this overshield is smaller than the current reference overshield so this becomes the new reference overshield
            
            reference_overshield=overshield
            radius_reference_overshield=overshield_r(overshield)
            
            write(*,*)'This cable reference overshield has been updated to',reference_overshield

          end if  ! is this the smallest overshield?
          
        end if  ! is cable within this overshield?
                 
      end do
      
      if (reference_overshield.NE.0) then
! this cable has been identified as being within an overshield

        if (overshield_domain(reference_overshield).EQ.0) then 
          
! this overshield domain is unallocated so create a new domain
  
          tot_n_domains=tot_n_domains+1
          n_overshield_domains=n_overshield_domains+1
          if(verbose) write(*,*)'Creating overshield domain=',tot_n_domains
          overshield_domain(reference_overshield)=tot_n_domains
            
          global_domain_reference_conductor(tot_n_domains)=overshield_reference_terminal_conductor(reference_overshield)
            
          write(*,*)'This overshield domain is unallocated so create a new domain, domain=',tot_n_domains
                        
        end if ! this overshield domain is unallocated
          
        cable_reference_domain(cable)=overshield_domain(reference_overshield)
          
        write(*,*)'Setting the cable reference domain to',overshield_domain(reference_overshield)
          
      end if   ! this cable is within the overshield
             
      terminal_conductor=terminal_conductor+bundle%cable(cable)%tot_n_conductors ! update the terminal conductor count
        
    else  ! THIS CABLE IS AN OVERSHIELD SO WE NEED TO CHECK WHETHER IT IS INSIDE ANY OTHER OVERSHIELDS   
   
      write(*,*)'THIS CABLE IS AN OVERSHIELD'
       
      cable_x=bundle%cable_x_offset(cable)
      cable_y=bundle%cable_y_offset(cable)
      cable_r=bundle%cable(cable)%parameters(1)  ! overshield radius
      
! find the smallest overshield enclosing this overshield if there is one   

      reference_overshield=0
      radius_reference_overshield=1d30
      
      do overshield=1,tot_n_overshields
      
        cable_t=overshield_to_cable_number(overshield)
        if (cable_t.NE.cable) then   ! don't check an overshield against itself
      
          dist_cable_to_overshield_centre=sqrt( (cable_x-overshield_x(overshield))**2+  &
                                                (cable_y-overshield_y(overshield))**2  )
                                              
          if ( dist_cable_to_overshield_centre.LT.overshield_r(overshield) ) then
! we conclude that this cable is within the overshield

            write(*,*)'This overshield centre is inside overshield number',overshield

!! Check that can be removed when we are happy with nexted overshields code            
!            run_status='ERROR, Nested overshields cannot be used in SACAMOS at the moment'
!            CALL write_program_status()
!            STOP 1

            if (radius_reference_overshield.GT.overshield_r(overshield)) then
! this overshield is smaller than the current reference overshield so this becomes the new reference overshield
            
              if (overshield_r(overshield).GT.cable_r) then
! the cable is smaller than the overshield and hence is inside it

! Check that the lowest number overshield is the smaller. Overshields should be numbered inside to out

                if (cable_t.LT.cable) then
              
                  run_status='ERROR, Nested overshields should be numbered in the order inside to out'
                  CALL write_program_status()
                  STOP 1
              
                end if

                write(*,*)'This overshield is smaller than the reference overshield and is therefore inside it'
           
                reference_overshield=overshield
                radius_reference_overshield=overshield_r(overshield)
            
                write(*,*)'This cable reference overshield has been updated to',reference_overshield
              
              end if  ! This overshield is smaller than the reference overshield and is therefore inside it
              
            end if  ! is this the smallest overshield?
          
          end if  ! is cable centre within this overshield?
          
        end if  ! don't check an overshield against itself
       
      end do
      
      if (reference_overshield.NE.0) then
! this cable has been identified as being within an overshield

        if (overshield_domain(reference_overshield).EQ.0) then 
          
! this overshield domain is unallocated so create a new domain
  
          tot_n_domains=tot_n_domains+1
          n_overshield_domains=n_overshield_domains+1
          if(verbose) write(*,*)'Creating overshield domain=',tot_n_domains
          overshield_domain(reference_overshield)=tot_n_domains
            
          global_domain_reference_conductor(tot_n_domains)=overshield_reference_terminal_conductor(reference_overshield)
            
          write(*,*)'This overshield domain is unallocated so create a new domain, domain=',tot_n_domains
                        
        end if ! this overshield domain is unallocated
          
        cable_reference_domain(cable)=overshield_domain(reference_overshield)
          
        write(*,*)'Setting the cable reference domain to',overshield_domain(reference_overshield)
          
      end if   ! this cable is within the overshield
             
      terminal_conductor=terminal_conductor+bundle%cable(cable)%tot_n_conductors ! update the terminal conductor count
     
       
    end if ! not an overshield
    
  end do ! next cable

  if (verbose) write(*,*) 'n_overshield_domains=',n_overshield_domains
  
  write(*,*)'**********************************************************************'

! 3c part 2. loop over the overshield domains and count the number of external conductors in each one  

  do overshield=1,tot_n_overshields
 
    terminal_conductor=0   ! count the terminal conductor number
    conductor_count=0      ! count the number of condcutors referenced to this overshield
    
    do cable=1,tot_n_cables_without_ground_plane
      
      if (cable_reference_domain(cable).EQ.overshield_domain(overshield)) then
! this cable contributes its external conductors to the overshield

        first_external_conductor=terminal_conductor+bundle%cable(cable)%tot_n_conductors-bundle%cable(cable)%n_external_conductors+1
        
        do conductor=1,bundle%cable(cable)%n_external_conductors
          conductor_count=conductor_count+1
          overshield_terminal_conductor(overshield,conductor_count)=first_external_conductor+(conductor-1)
        end do
        
      end if
      
      terminal_conductor=terminal_conductor+bundle%cable(cable)%tot_n_conductors ! update the terminal conductor count

    end do ! next cable  
    
    overshield_n_conductors(overshield)=conductor_count
    
  end do ! next overshield
  
  if (verbose) then
    write(*,*)
    write(*,*)'Overshield conductor information'
    do overshield=1,tot_n_overshields
      write(*,*)'Overshield:',overshield,' Number of condcutors=',overshield_n_conductors(overshield)
      write(*,*)' Overshield_conductor    terminal_conductor '
      do conductor=1,overshield_n_conductors(overshield)
        write(*,*)conductor,overshield_terminal_conductor(overshield,conductor)
      end do
    end do ! next overshield
    write(*,*)
  end if
  
! 3d. We now have unallocated reference domains, these are not in overshields so must be in the external domain

! 4. Count the number of conductors in the external domain to check whether it is viable i.e. at least 2 conductors

  bundle%tot_n_external_conductors=0
  do cable=1,tot_n_cables    
    if (cable_reference_domain(cable).EQ.0) then    
! this cable reference domain must be the external domain
      bundle%tot_n_external_conductors=bundle%tot_n_external_conductors+bundle%cable(cable)%n_external_conductors     
    end if ! reference domain not yet set    
  end do ! next cable
  
  if(verbose) write(*,*)'Number of conductors in external domain=',bundle%tot_n_external_conductors

! 4b.     Create an external domain and allocate unallocated reference domains now...
  ALLOCATE( external_terminal_conductor(1:bundle%tot_n_external_conductors) )
  external_terminal_conductor(1:bundle%tot_n_external_conductors)=0
  
  tot_n_viable_domains=tot_n_domains
  tot_n_domains=tot_n_domains+1
  
  if (bundle%tot_n_external_conductors.GT.1) then
    tot_n_viable_domains=tot_n_viable_domains+1
  end if
  
  if(verbose) write(*,*)'Creating external domain=',tot_n_domains
    
  terminal_conductor=0
  external_conductor_count=0
    
  do cable=1,tot_n_cables
    
    is_external_domain=.FALSE.
    if (cable_reference_domain(cable).EQ.0) then ! this cable reference domain must be the external domain
      cable_reference_domain(cable)=tot_n_domains
      is_external_domain=.TRUE.
    end if
      
    do local_conductor=1,bundle%cable(cable)%tot_n_conductors
    
      terminal_conductor=terminal_conductor+1
        
      if ( (is_external_domain).AND.(bundle%cable(cable)%local_reference_conductor(local_conductor).EQ.0) ) then        
        external_conductor_count=external_conductor_count+1
        external_terminal_conductor(external_conductor_count)=terminal_conductor      
      end if
        
    end do
        
    if (is_external_domain) then ! this cable reference domain must be the external domain
      global_domain_reference_conductor(tot_n_domains)=terminal_conductor
    end if
      
  end do ! next cable
    
! check the conductor count
  if (external_conductor_count.NE.bundle%tot_n_external_conductors) then
    run_status='ERROR in create_global_domain_structure: external_conductor_count.NE.bundle%tot_n_external_conductors'
    CALL write_program_status()
    STOP 1
  end if
  
  if(verbose) then  
    write(*,*)'External domain terminal conductors:'
    do conductor=1,bundle%tot_n_external_conductors
      write(*,*)'conductor=',external_terminal_conductor(conductor)
    end do ! next cable
  end if
  
  bundle%tot_n_domains=tot_n_viable_domains
  
  if(verbose) then  
    write(*,*)'Total number of domains=',tot_n_domains
    write(*,*)'Total number of viable domains=',tot_n_viable_domains
    write(*,*)'Cable reference domain numbers:'
    do cable=1,tot_n_cables  
      write(*,*)'cable=',cable,' reference domain=',cable_reference_domain(cable) 
    end do ! next cable
  end if
  
  ALLOCATE( domain_is_TP_differential_mode(1:tot_n_domains) )
  domain_is_TP_differential_mode(1:tot_n_domains)=.FALSE.

! 5. build the global_domain numbering, ignoring any unused domains

  conductor=0       ! this is the external conductor number
  domain_count=0
  conductor_count=0 ! this is the conductor count for the domain based numbering
  
! 5a. Count conductors from internal domains initially    
  do cable=1,tot_n_cables
  
    local_cable_conductor=0
    local_n_domains=bundle%cable(cable)%tot_n_domains
        
! 17/5/2017 CJS Add a check here to flag twisted pair differential mode domains
! The check is hrd wired based on cable types
 
    if (bundle%cable(cable)%cable_type.EQ.cable_geometry_type_twisted_pair) then 
    
      domain_is_TP_differential_mode(domain_count+1)=.TRUE.
      
    else if (bundle%cable(cable)%cable_type.EQ.cable_geometry_type_shielded_twisted_pair) then 
    
      domain_is_TP_differential_mode(domain_count+1)=.TRUE.

    else if (bundle%cable(cable)%cable_type.EQ.cable_geometry_type_spacewire) then 
    
      domain_is_TP_differential_mode(domain_count+1)=.TRUE.
      domain_is_TP_differential_mode(domain_count+3)=.TRUE.
      domain_is_TP_differential_mode(domain_count+5)=.TRUE.
      domain_is_TP_differential_mode(domain_count+7)=.TRUE.
    
    end if

! exclude the external domain  
    do local_domain=1,local_n_domains
    
      if (local_domain.NE.local_n_domains) then

! This is an internal domain so add to the domain count
        domain_count=domain_count+1
        domain=domain_count
      
        local_n_conductors=bundle%cable(cable)%local_domain_n_conductors(local_domain)-1 ! subtract 1 as the reference conductor is included
      
        do local_conductor=1,local_n_conductors
    
          conductor=conductor+1
          local_cable_conductor=local_cable_conductor+1
          conductor_count=conductor_count+1
          terminal_conductor_to_global_domain(conductor)=domain
          terminal_conductor_to_cable_local_domain(conductor)=local_conductor
          terminal_conductor_to_global_domain_conductor(conductor)=conductor_count                        
          bundle%cable(cable)%global_domain_conductor(local_cable_conductor)=conductor_count
          bundle%cable(cable)%terminal_conductor(local_cable_conductor)=conductor
       
        end do
        
      else
! This is an external domain so leave until later but count the global conductors.

        local_n_conductors=bundle%cable(cable)%local_domain_n_conductors(local_domain)-1 ! subtract 1 as the reference conductor is included     
        do local_conductor=1,local_n_conductors    
          conductor=conductor+1        
          local_cable_conductor=local_cable_conductor+1
        end do
      
      end if ! internal or external domain
      
    end do ! next conductor in this cable
    
  end do ! next cable

! 5b. Include the 'external' domain conductors now  
  do domain=first_external_domain,tot_n_domains
  
    conductor=0       ! this is the external conductor number
    do cable=1,tot_n_cables
  
      local_cable_conductor=0
      local_n_domains=bundle%cable(cable)%tot_n_domains

      do local_domain=1,local_n_domains
    
        if (local_domain.NE.local_n_domains) then

! This is an internal domain so this is already included, only count the conductors
      
          local_n_conductors=bundle%cable(cable)%local_domain_n_conductors(local_domain)-1 ! subtract 1 as the reference conductor is included
      
          do local_conductor=1,local_n_conductors
    
            conductor=conductor+1
            local_cable_conductor=local_cable_conductor+1
        
          end do
        
        else
! This is an external domain so add the conductors if it is the currrent external domain

          local_n_conductors=bundle%cable(cable)%local_domain_n_conductors(local_domain)-1 ! subtract 1 as the reference conductor is included     
          do local_conductor=1,local_n_conductors    
            conductor=conductor+1       
            local_cable_conductor=local_cable_conductor+1
            
            if (cable_reference_domain(cable).EQ.domain) then
            
              conductor_count=conductor_count+1       
              terminal_conductor_to_global_domain(conductor)=domain
              terminal_conductor_to_cable_local_domain(conductor)=local_conductor
              terminal_conductor_to_global_domain_conductor(conductor)=conductor_count                       
              bundle%cable(cable)%global_domain_conductor(local_cable_conductor)=conductor_count
              bundle%cable(cable)%terminal_conductor(local_cable_conductor)=conductor
              
            end if ! this external domain is the current one to be included
             
          end do ! next local conductor
      
        end if ! internal or external domain
        
      end do ! next local domain
           
    end do ! next cable
    
  end do ! next external domain
  
! 5c. Set the  global_domain_conductor_to_terminal_conductor from terminal_conductor_to_global_domain_conductor
  
  if (verbose) then
  
    write(*,*)'conductor,terminal_conductor_to_global_domain_conductor(conductor)'
    
    do conductor=1,tot_n_conductors
      write(*,*)conductor,terminal_conductor_to_global_domain_conductor(conductor)
    end do 
        
  end if 
  
! loop over terminal conductors
  do conductor=1,tot_n_conductors
    global_domain_conductor_to_terminal_conductor(terminal_conductor_to_global_domain_conductor(conductor))=conductor
  end do 
  
  if (verbose) then
  
    write(*,*)'conductor,global_domain_conductor_to_terminal_conductor(conductor)'
    
    do conductor=1,tot_n_conductors
      write(*,*)conductor,global_domain_conductor_to_terminal_conductor(conductor)
    end do 
        
  end if 

! 22/10/2019 CJS Fix bug with numbering here: overshields were numbered using terminal conductor number
!                not global domain conductor as it should be at this stage
! 5d. Renumber the reference conductors for overshield domains. At the moment these are terminal conductors
!     not global domain conductors

  do overshield=1,tot_n_overshields
  
    domain=overshield_domain(overshield)

    reference_conductor=global_domain_reference_conductor(domain)
      
    global_reference_conductor=terminal_conductor_to_global_domain_conductor(reference_conductor)
    global_domain_reference_conductor(domain)=global_reference_conductor

  end do ! next overshield 
   
! 5e. Set the global_domain_reference_conductor information, also flag all the reference conductors in internal domains
  
  conductor=0       ! this is the external conductor number
  
  write(*,*)
  write(*,*)
  write(*,*)'    terminal     cable      local    local_domain   global      cable     local_ref   ref terminal   ref global     '
  write(*,*)'    conductor              domain     conductor     domain     conductor  conductor    conductor    domain conductor'
  
  do cable=1,tot_n_cables
  
    local_n_domains=bundle%cable(cable)%tot_n_domains
    
    local_cable_conductor=0

    do local_domain=1,local_n_domains
          
      local_n_conductors=bundle%cable(cable)%local_domain_n_conductors(local_domain)-1 ! subtract 1 as the reference conductor is included
                  
      do local_domain_conductor=1,local_n_conductors
      
        conductor=conductor+1
        local_cable_conductor=local_cable_conductor+1
        
        reference_conductor=bundle%cable(cable)%local_reference_conductor(local_cable_conductor)
        
        if (reference_conductor.NE.0) then
! the reference conductor is defined locally        
          terminal_conductor_to_reference_global_domain_conductor(conductor)=   &
                      bundle%cable(cable)%global_domain_conductor(reference_conductor)

! 27/4/2016 CJS                      
          domain=terminal_conductor_to_global_domain(conductor)
! 16/5/2016 this should be the global not the local number...          global_domain_reference_conductor(domain)=reference_conductor
          global_domain_reference_conductor(domain)=bundle%cable(cable)%global_domain_conductor(reference_conductor)
                               
        else
        
! the reference conductor is defined in terms of the reference domain of the cable         
   
          domain=cable_reference_domain(cable) 
          
          global_reference_conductor=global_domain_reference_conductor(domain)     
          
          reference_conductor=global_domain_conductor_to_terminal_conductor(global_reference_conductor)
          
          terminal_conductor_to_reference_global_domain_conductor(conductor)=  &
                    terminal_conductor_to_global_domain_conductor(reference_conductor)
                    
          reference_conductor=0
                    
        end  if
        
        local_conductor=terminal_conductor_to_reference_global_domain_conductor(conductor)
        terminal_conductor_to_reference_terminal_conductor(conductor)=  &
          global_domain_conductor_to_terminal_conductor(local_conductor)
          
        terminal_conductor_is_reference_conductor(terminal_conductor_to_reference_terminal_conductor(conductor))=.TRUE.
        
        write(*,8000)bundle%cable(cable)%terminal_conductor(local_cable_conductor),&
                     cable,local_domain,local_domain_conductor, &
                     terminal_conductor_to_global_domain(conductor),    &
                     local_cable_conductor,reference_conductor, &
                     terminal_conductor_to_reference_terminal_conductor(conductor), &
                     terminal_conductor_to_reference_global_domain_conductor(conductor)
8000 format(5I11,4I13)
                            
      end do ! next local domain conductor
        
    end do ! next local domain
           
  end do ! next cable
  
   
! 6.  Now that we have counted the number of domains we can allocate the 
!     domain based number of conductors and L and C matrices plus
!     the global MI and MV matrices 

! Note: this allocation includes non-viable domains
  ALLOCATE( bundle%n_conductors(1:tot_n_domains) ) 
  bundle%n_conductors(1:tot_n_domains)=0
  
  ALLOCATE( bundle%L(1:tot_n_domains) ) 
  ALLOCATE( bundle%C(1:tot_n_domains) )
  ALLOCATE( bundle%Z(1:tot_n_domains) ) 
  ALLOCATE( bundle%Y(1:tot_n_domains) )

! 6a. Count the number of conductors in each domain
  if (verbose) write(*,*)'terminal_conductor   domain   local_domain_conductor'
  do conductor=1,tot_n_conductors 
    domain=terminal_conductor_to_global_domain(conductor)
    bundle%n_conductors(domain)=bundle%n_conductors(domain)+1

! 4/10/2016 Save the local domain coonductor numbering
    bundle%terminal_conductor_to_local_domain_conductor(conductor)=bundle%n_conductors(domain)
    
    if (verbose) write(*,*)conductor,domain,bundle%terminal_conductor_to_local_domain_conductor(conductor)

  end do ! next conductor
  
! Note there may be unviable overshield domains which need to be excluded in the following loop...  
  
! internal  domains and overshield domains don't include the reference conductor so add this here
  do domain=1,tot_n_internal_domains+n_overshield_domains
    bundle%n_conductors(domain)=bundle%n_conductors(domain)+1
  end do
  
  if (verbose) then
    write(*,*)
    write(*,*)'Number of conductors in each domain'
    write(*,*)'       domain     n_conductors'
    do domain=1,tot_n_domains
      write(*,*)domain,bundle%n_conductors(domain)
    end do
  end if
  
! allocate the global voltage and current domain transformation matrices
! strictly the dimension should be bundle%tot_n_conductors-1
! this would require many checks later on to prevent array bounds problems with no ground plane specified
! so we allocate the extra space then ignore the last row and col when doing the domain decomposition

  dim=bundle%tot_n_conductors
  
  if(verbose) then
    write(*,*)'ALLOCATING global_MI and global_MV, dimension:',dim
  end if

  bundle%global_MI%dim=dim
  ALLOCATE( bundle%global_MI%mat(1:dim,1:dim) ) 
  bundle%global_MI%mat(1:dim,1:dim)=0d0

  bundle%global_MV%dim=dim
  ALLOCATE( bundle%global_MV%mat(1:dim,1:dim) ) 
  bundle%global_MV%mat(1:dim,1:dim)=0d0

! Allocate the conductor based impedance (loss) model and reset all the parameters
  ALLOCATE( bundle%conductor_impedance(1:dim) )
  do conductor=1,bundle%tot_n_conductors
    bundle%conductor_impedance(conductor)%radius=0d0
    bundle%conductor_impedance(conductor)%width=0d0
    bundle%conductor_impedance(conductor)%height=0d0
    bundle%conductor_impedance(conductor)%conductivity=0d0
    bundle%conductor_impedance(conductor)%thickness=0d0
    bundle%conductor_impedance(conductor)%Resistance_multiplication_factor=1d0
  end do
  
! allocate the global inductance and capacitance matrices - these are used in the analytic solution
! which is used for validation

  dim=bundle%tot_n_conductors-1 
  
  if(verbose) then
    write(*,*)'ALLOCATING global_L and global_C, dimension:',dim
  end if

  bundle%global_L%dim=dim
  ALLOCATE( bundle%global_L%mat(1:dim,1:dim) ) 
  bundle%global_L%mat(1:dim,1:dim)=0d0

  bundle%global_C%dim=dim
  ALLOCATE( bundle%global_C%mat(1:dim,1:dim) ) 
  bundle%global_C%mat(1:dim,1:dim)=0d0

  if(verbose) then
    write(*,*)'ALLOCATING global_Z and global_Y, dimension:',dim
  end if
  bundle%global_Z%dim=dim
  ALLOCATE( bundle%global_Z%sfilter_mat(1:dim,1:dim) ) 
  do row=1,dim
    do col=1,dim
      bundle%global_Z%sfilter_mat(row,col)=0d0         ! set all filters to zero filter for now
    end do
  end do
  
  bundle%global_Y%dim=dim
  ALLOCATE( bundle%global_Y%sfilter_mat(1:dim,1:dim) ) 
  do row=1,dim
    do col=1,dim
      bundle%global_Y%sfilter_mat(row,col)=0d0        ! set all filters to zero filter for now
    end do
  end do
  
! Allocate the domain based terminal conductor list  CJS 27/4/2016
  ALLOCATE( bundle%terminal_conductor_list(1:bundle%tot_n_domains))
  
! 6b. Copy the cable based internal domain L and C matrices to bundle structure
!     and construct the global MI and MV matrices from the cable based structures 
 
  terminal_conductor=0       ! this is the external conductor number
  domain_count=0
  
  if (verbose) then
    write(*,*)''
    write(*,*)'SET MI, MV matrices'
    write(*,*)''
  end if
  
  do cable=1,tot_n_cables_without_ground_plane
  
    local_n_domains=bundle%cable(cable)%tot_n_domains
    
    local_cable_conductor=0
    n_cable_conductors=bundle%cable(cable)%tot_n_conductors
        
! copy the cable based MI and MV matrices to the global structure. The cable based
! MI and MV matrices are on the basis of terminal_conductor numbering
    if (verbose) then
      write(*,*)''
      write(*,*)'Copy MI, MV, cable=',cable,' of', tot_n_cables_without_ground_plane
      write(*,*)'Matrix dimension',n_cable_conductors+1
      write(*,*)'intial terminal_conductor count=',terminal_conductor
    end if
    
    do row_l=1,n_cable_conductors+1 ! add 1 as the reference conductor must be included
                
      do col_l=1,n_cable_conductors+1 ! add 1 as the reference conductor must be included

! In the global MI, MV structure rows correspond to the global domain conductor number, cols correspond to the terminal conductor number 
        
        if (row_l.NE.n_cable_conductors+1) then
          row_g=terminal_conductor_to_global_domain_conductor(terminal_conductor+row_l)
        else
          row_g=terminal_conductor_to_reference_global_domain_conductor(terminal_conductor+row_l-1) ! last conductor for this cable and the reference    
        end if
     
        if (col_l.NE.n_cable_conductors+1) then
          col_g=terminal_conductor+col_l
        else
          col_g=terminal_conductor_to_reference_terminal_conductor(terminal_conductor+col_l-1) ! last conductor for this cable and the reference
        end if
        
        bundle%global_MI%mat(row_g,col_g)=bundle%cable(cable)%MI%mat(row_l,col_l)
        bundle%global_MV%mat(row_g,col_g)=bundle%cable(cable)%MV%mat(row_l,col_l)
        
!      if (verbose) write(*,*)'Copy MV element',row_g,col_g,bundle%global_MV%mat(row_g,col_g)

          if (verbose) then
          write(*,*)'Copy MI element',' row_g=',row_g,' col_g=',col_g,      &
                                    ' row_l=',row_l,' col_l=',col_l,bundle%cable(cable)%MI%mat(row_l,col_l)
        end if
        
      end do ! next col
      
    end do ! next row
    
    if (bundle%cable(cable)%cable_type.EQ.cable_geometry_type_overshield) then 
! This is an overshield so invoke the special process for overshields

! Get the global domain number of the shield conductor
      row_g=terminal_conductor_to_global_domain_conductor(terminal_conductor+1)
      
! Get the global domain number of the shield reference conductor
      row_g_ref=terminal_conductor_to_reference_global_domain_conductor(terminal_conductor+1)
      
! Add all the non-zero elements of the MI matrix shield row to the shield reference row

      write(*,*)'Overshield cable',cable,' Copying row',row_g,' to row',row_g_ref
                      
      do col_g=1,bundle%global_MI%dim

! In the global MI, MV structure rows correspond to the global domain conductor number, cols correspond to the terminal conductor number 
                
        if (bundle%global_MI%mat(row_g,col_g).NE.0d0) then
        
          bundle%global_MI%mat(row_g_ref,col_g)=bundle%global_MI%mat(row_g,col_g)
        
        end if
                
      end do ! next col
      
    end if ! overshield
    
    do local_domain=1,local_n_domains  ! exclude the external domain for now
    
      if (local_domain.NE.local_n_domains) then

! This is an internal domain so add to the domain count
        
        domain_count=domain_count+1 
        domain=domain_count
        
! 6c copy the domain based L and C matrices to the domain based L and C in the bundle structure                       #

        if (verbose) write(*,*)'Copy the domain based L and C matrices to the domain based L and C in the bundle structure'

        if (verbose) write(*,*)'domain=',domain   
 
        dim=bundle%cable(cable)%L_domain(local_domain)%dim
        ALLOCATE( bundle%L(domain)%mat(dim,dim) ) 
        bundle%L(domain)%dim=dim
        if (verbose) write(*,*)'Allocating bundle%L(domain)        ,dim=',dim
        
        dim=bundle%cable(cable)%C_domain(local_domain)%dim
        ALLOCATE( bundle%C(domain)%mat(dim,dim) ) 
        bundle%C(domain)%dim=dim
        if (verbose) write(*,*)'Allocating bundle%C(domain)        ,dim=',dim
 
        dim=bundle%cable(cable)%Z_domain(local_domain)%dim
        ALLOCATE( bundle%Z(domain)%sfilter_mat(dim,dim) ) 
        bundle%Z(domain)%dim=dim
        if (verbose) write(*,*)'Allocating bundle%Z(domain)        ,dim=',dim
        
        dim=bundle%cable(cable)%Y_domain(local_domain)%dim
        ALLOCATE( bundle%Y(domain)%sfilter_mat(dim,dim) ) 
        bundle%Y(domain)%dim=dim
        if (verbose) write(*,*)'Allocating bundle%Y(domain)        ,dim=',dim
      
        local_n_conductors=bundle%cable(cable)%local_domain_n_conductors(local_domain)
      
        do row_l=1,local_n_conductors-1 ! subtract 1 as the reference conductor is included
                    
          do col_l=1,local_n_conductors-1 ! subtract 1 as the reference conductor is included
          
            bundle%L(domain)%mat(row_l,col_l)=bundle%cable(cable)%L_domain(local_domain)%mat(row_l,col_l)      
            bundle%C(domain)%mat(row_l,col_l)=bundle%cable(cable)%C_domain(local_domain)%mat(row_l,col_l)
            
            bundle%Z(domain)%sfilter_mat(row_l,col_l)=bundle%cable(cable)%Z_domain(local_domain)%sfilter_mat(row_l,col_l)      
            bundle%Y(domain)%sfilter_mat(row_l,col_l)=bundle%cable(cable)%Y_domain(local_domain)%sfilter_mat(row_l,col_l)

! copy the domain based L and C matrices to the global L and C in the bundle structure                        

! in the global L,C structure rows and columns correspond to the global_domain conductor number
            row_g=terminal_conductor_to_global_domain_conductor(terminal_conductor+row_l)
            col_g=terminal_conductor_to_global_domain_conductor(terminal_conductor+col_l)

            bundle%global_L%mat(row_g,col_g)=bundle%L(domain)%mat(row_l,col_l)
            bundle%global_C%mat(row_g,col_g)=bundle%C(domain)%mat(row_l,col_l)

            bundle%global_Z%sfilter_mat(row_g,col_g)=bundle%Z(domain)%sfilter_mat(row_l,col_l)
            bundle%global_Y%sfilter_mat(row_g,col_g)=bundle%Y(domain)%sfilter_mat(row_l,col_l)
         
          end do ! next column of matrix
          
        end do ! next row of matrix

! Added CJS 27/4/2016
        bundle%terminal_conductor_list(domain)%n_elements=local_n_conductors
        ALLOCATE( bundle%terminal_conductor_list(domain)%element(1:local_n_conductors) )
        
        do conductor=1,local_n_conductors-1   ! do reference conductor separately    
        
          bundle%terminal_conductor_list(domain)%element(conductor)=terminal_conductor+conductor    
            
        end do ! next conductor in this domain
        
! reference conductor        
        reference_conductor=global_domain_reference_conductor(domain)       ! note domain based numbering...
        write(*,*)'Domain=',domain
        write(*,*)'Global domain reference conductor=',reference_conductor
        bundle%terminal_conductor_list(domain)%element(local_n_conductors)=  &
                                               global_domain_conductor_to_terminal_conductor(reference_conductor)
          
        terminal_conductor=terminal_conductor+local_n_conductors-1  ! subtract 1 as the count includes the reference conductor

      else
! This is an external domain so leave until later but count the global conductors.

        local_n_conductors=bundle%cable(cable)%local_domain_n_conductors(local_domain)-1 ! subtract 1 as the reference conductor is included     
        do local_conductor=1,local_n_conductors    
          terminal_conductor=terminal_conductor+1        
        end do
      
      end if ! internal or external domain

    end do ! next local domain
    
  end do ! next cable
    
! 7. Calculate the inductance and capacitance matrices for the external domains (domains within overshields and the external domain)

  if(verbose) write(*,*)'first external domain:',first_external_domain
  if(verbose) write(*,*)'total number of domains:',tot_n_domains
  
  overshield=0    ! counter for overshield domains

  do domain=first_external_domain,tot_n_viable_domains   ! exclude the external domain if there is only one conductor
  
! allocate memory for the PUL parameter solver interface

    if(verbose) write(*,*)'Domain:',domain
    if(verbose) write(*,*)'Allocating PUL data structure for ',bundle%n_conductors(domain),' conductors'
    
    CALL allocate_and_reset_PUL_data(PUL,bundle%n_conductors(domain))
     
! copy external conductor information to the PUL structure

    conductor=0        ! this provides a count of the external domain conductor numbering for PUL parameter calculation
  
! loop over cables  
    do cable=1,bundle%n_cables
    
      if (cable_reference_domain(cable).EQ.domain) then
      
! The reference domain of this cable is the domain we are currently working on so add the external 
! conductor information for this cable to the PUL structure

        do local_conductor=1,bundle%cable(cable)%n_external_conductors
      
          if (bundle%cable(cable)%cable_type.NE.cable_geometry_type_ground_plane) then
             
            conductor=conductor+1  ! add another conductor to the external domain
         
            if(verbose) write(*,*)'Adding conductor number',local_conductor,' from cable',cable,'. Domain conductor',conductor
      
            PUL%shape(conductor)=bundle%cable(cable)%external_model(local_conductor)%conductor_type
            PUL%x(conductor)=bundle%cable_x_offset(cable)    
            PUL%y(conductor)=bundle%cable_y_offset(cable)   
            PUL%rtheta(conductor)=bundle%cable_angle(cable)
            
            PUL%ox(conductor)=bundle%cable(cable)%external_model(local_conductor)%conductor_ox
            PUL%oy(conductor)=bundle%cable(cable)%external_model(local_conductor)%conductor_oy
            PUL%r(conductor)=bundle%cable(cable)%external_model(local_conductor)%conductor_radius
            PUL%rw(conductor)=bundle%cable(cable)%external_model(local_conductor)%conductor_width
            PUL%rw2(conductor)=bundle%cable(cable)%external_model(local_conductor)%conductor_width2
            PUL%rh(conductor)=bundle%cable(cable)%external_model(local_conductor)%conductor_height
            PUL%rd(conductor)=bundle%cable(cable)%external_model(local_conductor)%dielectric_radius
            PUL%rdw(conductor)=bundle%cable(cable)%external_model(local_conductor)%dielectric_width
            PUL%rdh(conductor)=bundle%cable(cable)%external_model(local_conductor)%dielectric_height
            PUL%rdox(conductor)=bundle%cable(cable)%external_model(local_conductor)%dielectric_ox
            PUL%rdoy(conductor)=bundle%cable(cable)%external_model(local_conductor)%dielectric_oy
            PUL%epsr(conductor)=bundle%cable(cable)%external_model(local_conductor)%dielectric_epsr 
               
          end if ! not a ground plane    
              
        end do ! next cable external conductor
              
      end if  ! cable contributes to this domain
          
    end do ! next cable
   
! Calculate the per-unit-length parameters (inductance and capacitance matrices)
    
! if this is an overshield domain then
    if (verbose) write(*,*)'domain=',domain,' last domain(check)=',first_external_domain+tot_n_overshields
    if(domain.LT.(first_external_domain+n_overshield_domains)) then
    
      overshield=overshield+1

      if (verbose) write(*,*)'PUL parameter calculation for oversheild domain'
! no ground plane
      PUL%ground_plane_present=.FALSE.
      PUL%ground_plane_angle  =0d0
      PUL%ground_plane_offset =0d0
     
! add overshield information   
      if (verbose) write(*,*)'Add overshield information'
      is_overshield_domain=.TRUE.
      PUL%overshield_present=.TRUE.
      overshield=domain-first_external_domain+1
      PUL%overshield_shape = overshield_shape(overshield)
      PUL%overshield_x = overshield_x(overshield)
      PUL%overshield_y = overshield_y(overshield)
      PUL%overshield_r = overshield_r(overshield)
      PUL%overshield_w = overshield_w(overshield)
      PUL%overshield_w2 = overshield_w2(overshield)
      PUL%overshield_h = overshield_h(overshield)
      
      PUL%epsr_background = 1d0 ! background permittivity =1.0 within an overshield i.e. cables are in air
      
      if (use_Laplace) then
      
         CALL PUL_LC_Laplace(PUL,bundle%bundle_name,bundle%Y_fit_model_order,bundle%Y_fit_freq_spec,domain)
      
      else
      
        if (verbose) write(*,*)'CALL PUL_LC_calc_overshield_wide_separation_approximation'
        CALL PUL_LC_calc_overshield_wide_separation_approximation(PUL)
        
      end if ! use_Laplace or not...

    else
! this is an external domain    
    
! copy ground plane information
      PUL%ground_plane_present=bundle%ground_plane_present
      PUL%ground_plane_angle  =bundle%ground_plane_angle
      PUL%ground_plane_offset =bundle%ground_plane_offset
     
! No overshield information   
      is_overshield_domain=.FALSE.
      PUL%overshield_present=.FALSE.
      PUL%overshield_shape=0
      PUL%overshield_r= 0d0
      PUL%overshield_w= 0d0
      PUL%overshield_w2= 0d0
      PUL%overshield_h= 0d0
      
      PUL%epsr_background = 1d0 ! background permittivity =1.0 i.e. cables are in air

      if (use_Laplace) then
      
         CALL PUL_LC_Laplace(PUL,bundle%bundle_name,bundle%Y_fit_model_order,bundle%Y_fit_freq_spec,domain)
      
      else

        CALL PUL_LC_calc_wide_separation_approximation(PUL)

      end if ! use_Laplace or not...

    end if  ! last external domain (i.e. not an overshield domain)

! We now have the L and C matrices for this external domain        
! Copy the domain based L and C matrices to the domain based L and C in the bundle structure        
                
    if (verbose) write(*,*)'domain=',domain
    
    dim=PUL%L%dim
    if (verbose)  write(*,*)'Allocating bundle%L(domain)        ,dim=',dim
    ALLOCATE( bundle%L(domain)%mat(dim,dim) ) 
    bundle%L(domain)%dim=dim
    
    dim=PUL%C%dim
    if (verbose) write(*,*)'Allocating bundle%C(domain)        ,dim=',dim
    ALLOCATE( bundle%C(domain)%mat(dim,dim) ) 
    bundle%C(domain)%dim=dim
    
    dim=PUL%Zfilter%dim
    if (verbose) write(*,*)'Allocating bundle%Z(domain)        ,dim=',dim
    Bundle%Z(domain)%dim=dim
    ALLOCATE(Bundle%Z(domain)%sfilter_mat(dim,dim))
    
    dim=PUL%Yfilter%dim
    if (verbose) write(*,*)'Allocating bundle%Y(domain)        ,dim=',dim
    Bundle%Y(domain)%dim=dim
    ALLOCATE(Bundle%Y(domain)%sfilter_mat(dim,dim))
     
    local_n_conductors=bundle%n_conductors(domain) 
    
    if (is_overshield_domain) then
    
      if (verbose) write(*,*)'Copying L, C, Z, Y matrices in overshield domain, n_conductors=',local_n_conductors, &
                             overshield_n_conductors(overshield)+1
      
      do row_l=1,local_n_conductors-1 ! Note that the reference conductor is included in the conductor count here
               
        do col_l=1,local_n_conductors-1 ! Note that the reference conductor is included in the conductor count here
     
! In the global L,C structure rows and columns correspond to the global_domain conductor number
          row_g=terminal_conductor_to_global_domain_conductor(overshield_terminal_conductor(overshield,row_l))
          col_g=terminal_conductor_to_global_domain_conductor(overshield_terminal_conductor(overshield,col_l))
          
          bundle%L(domain)%mat(row_l,col_l)=PUL%L%mat(row_l,col_l)      
          bundle%C(domain)%mat(row_l,col_l)=PUL%C%mat(row_l,col_l)
          
          bundle%Z(domain)%sfilter_mat(row_l,col_l)=PUL%Zfilter%sfilter_mat(row_l,col_l)
          bundle%Y(domain)%sfilter_mat(row_l,col_l)=PUL%Yfilter%sfilter_mat(row_l,col_l)
          
! copy the domain based L and C matrices to the global L and C in the bundle structure                        
          bundle%global_L%mat(row_g,col_g)=bundle%L(domain)%mat(row_l,col_l)
          bundle%global_C%mat(row_g,col_g)=bundle%C(domain)%mat(row_l,col_l)
          
! copy the domain based Z and Y filter matrices to the global Z and Y in the bundle structure                        
          bundle%global_Z%sfilter_mat(row_g,col_g)=bundle%Z(domain)%sfilter_mat(row_l,col_l)
          bundle%global_Y%sfilter_mat(row_g,col_g)=bundle%Y(domain)%sfilter_mat(row_l,col_l)
         
        end do ! next column of matrix
          
      end do ! next row of matrix

! Added CJS 27/4/2016
      bundle%terminal_conductor_list(domain)%n_elements=local_n_conductors
      ALLOCATE( bundle%terminal_conductor_list(domain)%element(1:local_n_conductors) )
        
      do conductor=1,local_n_conductors-1   ! do reference conductor separately    
        
        bundle%terminal_conductor_list(domain)%element(conductor)=overshield_terminal_conductor(overshield,conductor)
            
      end do ! next conductor in this domain
        
! reference conductor        
      reference_conductor=global_domain_reference_conductor(domain)       ! note domain based numbering...
      bundle%terminal_conductor_list(domain)%element(local_n_conductors)=  &
                                               global_domain_conductor_to_terminal_conductor(reference_conductor)

    else
! external domain
     
      write(*,*)'External domain, n_conductors=',local_n_conductors,' dim=',local_n_conductors-1 
     
      do row_l=1,local_n_conductors-1 ! subtract 1 as the reference conductor is included
               
        do col_l=1,local_n_conductors-1 ! subtract 1 as the reference conductor is included
        
! In the global L,C structure rows and columns correspond to the bundle_domain conductor number
          row_g=terminal_conductor_to_global_domain_conductor(external_terminal_conductor(row_l))
          col_g=terminal_conductor_to_global_domain_conductor(external_terminal_conductor(col_l))
          
          if (verbose) write(*,*)'Copy L,C from PUL structure'
          bundle%L(domain)%mat(row_l,col_l)=PUL%L%mat(row_l,col_l)      
          bundle%C(domain)%mat(row_l,col_l)=PUL%C%mat(row_l,col_l)
          
          if (verbose) write(*,*)'Copy Z,Y from PUL structure'
          bundle%Z(domain)%sfilter_mat(row_l,col_l)=PUL%Zfilter%sfilter_mat(row_l,col_l)
          bundle%Y(domain)%sfilter_mat(row_l,col_l)=PUL%Yfilter%sfilter_mat(row_l,col_l)

! copy the domain based L and C matrices to the global L and C in the bundle structure                        
          if (verbose) write(*,*)'Copy L,C from bundle structure'
          bundle%global_L%mat(row_g,col_g)=bundle%L(domain)%mat(row_l,col_l)
          bundle%global_C%mat(row_g,col_g)=bundle%C(domain)%mat(row_l,col_l)
          
          if (verbose) write(*,*)'Copy Z,Y from bundle structure'
 ! copy the domain based Z and Y filter matrices to the global Z and Y in the bundle structure                        
          bundle%global_Z%sfilter_mat(row_g,col_g)=bundle%Z(domain)%sfilter_mat(row_l,col_l)
          bundle%global_Y%sfilter_mat(row_g,col_g)=bundle%Y(domain)%sfilter_mat(row_l,col_l)
         
        end do ! next column of matrix
          
      end do ! next row of matrix
      
! Added CJS 27/4/2016
      bundle%terminal_conductor_list(domain)%n_elements=local_n_conductors
      ALLOCATE( bundle%terminal_conductor_list(domain)%element(1:local_n_conductors) )
        
      do conductor=1,local_n_conductors-1   ! do reference conductor separately    
        
        bundle%terminal_conductor_list(domain)%element(conductor)=external_terminal_conductor(conductor)  
            
      end do ! next conductor in this domain
        
! reference conductor        
      reference_conductor=global_domain_reference_conductor(domain)       ! note domain based numbering...
      bundle%terminal_conductor_list(domain)%element(local_n_conductors)=  &
                                               global_domain_conductor_to_terminal_conductor(reference_conductor)
      
    end if ! external domain
    
    CALL deallocate_PUL_data(PUL)

  end do ! next external domain

! 8. Copy the cable based conductor impedance (loss) models to the bundle structure

  conductor=0  ! count of terminal conductors
  
  do cable=1,tot_n_cables
                    
      do local_conductor=1,bundle%cable(cable)%tot_n_conductors
      
        conductor=conductor+1
! copy the conductor impedance model for this cable conductor to the bundle structure        
        
        bundle%conductor_impedance(conductor)%impedance_model_type=  &
                    bundle%cable(cable)%conductor_impedance(local_conductor)%impedance_model_type
        

        bundle%conductor_impedance(conductor)%radius=  &
                    bundle%cable(cable)%conductor_impedance(local_conductor)%radius

        bundle%conductor_impedance(conductor)%width=  &
                    bundle%cable(cable)%conductor_impedance(local_conductor)%width

        bundle%conductor_impedance(conductor)%height=  &
                    bundle%cable(cable)%conductor_impedance(local_conductor)%height
                    
        bundle%conductor_impedance(conductor)%conductivity=  &
                    bundle%cable(cable)%conductor_impedance(local_conductor)%conductivity
                    
        bundle%conductor_impedance(conductor)%thickness=  &
                    bundle%cable(cable)%conductor_impedance(local_conductor)%thickness
              
        bundle%conductor_impedance(conductor)%Resistance_multiplication_factor=  &
                    bundle%cable(cable)%conductor_impedance(local_conductor)%Resistance_multiplication_factor
                    
        if((bundle%conductor_impedance(conductor)%impedance_model_type.EQ.impedance_model_type_filter).OR. &  
           (bundle%conductor_impedance(conductor)%impedance_model_type.EQ.impedance_model_type_cylindrical_shield)) then
                                
          bundle%conductor_impedance(conductor)%ZT_filter=   &
                 bundle%cable(cable)%conductor_impedance(local_conductor)%ZT_filter
                               
        end if
    
      end do ! next conductor on this cable
      
  end do ! next cable

! 8b. Copy the cable based conductor labels to the bundle structure

  ALLOCATE( bundle%conductor_label(1:bundle%tot_n_conductors) )
  conductor=0  ! count of terminal conductors
  
  do cable=1,tot_n_cables
                    
      do local_conductor=1,bundle%cable(cable)%tot_n_conductors
      
        conductor=conductor+1
! copy the conductor impedance model for this cable conductor to the bundle structure        
        write(conductor_string,'(I3)')conductor
        bundle%conductor_label(conductor)='Conductor number '//conductor_string//'. '//  &
                                          trim(bundle%cable(cable)%conductor_label(local_conductor))
    
      end do ! next conductor on this cable
      
  end do ! next cable
  
! 9 save numbering information required for the transfer impedance calculation

! first loop over shielded domains. The reference conductor for each domain is a shield (by definition) 
! apart from the shielded twisted pair differential mode exception
! so record this hence set out the inner domain number for shields

write(*,*)'****************************************************************'

  do domain=1,bundle%tot_n_domains-1   ! note we exclude the exterior domain here
  
    reference_conductor=global_domain_reference_conductor(domain)
    terminal_conductor=global_domain_conductor_to_terminal_conductor(reference_conductor)  
    
    write(*,*)'domain=',domain,' reference_conductor=',reference_conductor,' terminal_conductor=',terminal_conductor
    
    if (.NOT.domain_is_TP_differential_mode(domain)) then
      bundle%terminal_conductor_is_shield_flag(terminal_conductor)=.TRUE.
      bundle%terminal_conductor_to_inner_domain(terminal_conductor)=domain
    end if
    
  end do ! next conductor
  
write(*,*)'****************************************************************'
 
! work out the outer domain for each conductor and the associated reference conductor
  do conductor=1,bundle%tot_n_conductors
  
    bundle%terminal_conductor_to_outer_domain(conductor)=terminal_conductor_to_global_domain(conductor)   
    bundle%terminal_conductor_to_global_domain_conductor(conductor)=terminal_conductor_to_global_domain_conductor(conductor)   
    bundle%terminal_conductor_to_reference_terminal_conductor(conductor)=   &
           terminal_conductor_to_reference_terminal_conductor(conductor)    
           
  end do ! next conductor
    
! 10. finish up

  if (allocated( overshield_shape )) DEALLOCATE( overshield_shape)
  if (allocated( overshield_x )) DEALLOCATE( overshield_x)
  if (allocated( overshield_y )) DEALLOCATE( overshield_y)
  if (allocated( overshield_r )) DEALLOCATE( overshield_r)
  if (allocated( overshield_w )) DEALLOCATE( overshield_w)
  if (allocated( overshield_w2 )) DEALLOCATE( overshield_w2)
  if (allocated( overshield_h )) DEALLOCATE( overshield_h)
  if (allocated( overshield_domain )) DEALLOCATE( overshield_domain)
  if (allocated( overshield_reference_terminal_conductor)) DEALLOCATE( overshield_reference_terminal_conductor )
  if (allocated( overshield_to_cable_number)) DEALLOCATE( overshield_to_cable_number )
  if (allocated( global_domain_reference_conductor )) DEALLOCATE( global_domain_reference_conductor )
  DEALLOCATE( cable_reference_conductor  )
  DEALLOCATE( cable_reference_domain  )
 
! Deallocate the referencing arrays
 
  DEALLOCATE( terminal_conductor_to_cable )  
  DEALLOCATE( terminal_conductor_to_cable_local_domain )  
  DEALLOCATE( terminal_conductor_to_global_domain )  
  DEALLOCATE( terminal_conductor_to_global_domain_conductor )  
  DEALLOCATE( terminal_conductor_to_reference_global_domain_conductor )  
  DEALLOCATE( terminal_conductor_to_reference_terminal_conductor )  
  DEALLOCATE( terminal_conductor_is_reference_conductor )  
  DEALLOCATE( global_domain_conductor_to_terminal_conductor )  
  DEALLOCATE( external_terminal_conductor )

  if (allocated( domain_is_TP_differential_mode )) DEALLOCATE( domain_is_TP_differential_mode )

END SUBROUTINE create_global_domain_structure