ZT_FD_rg223_innershield.cable_spec
1.28 KB
#MOD_cable_lib_dir
./
ZT_FD_coaxial2
2 # number of conductors
6 # NUMBER OF PARAMETERS
0.000472 # parameter 1: inner conductor radius (m)
0.00174 # Parameter 2 Shield radius (m)
0.002 # parameter 3: outer insulation radius (m)
0.0 # parameter 4: inner conductor electric conductivity
1.13e-4 # Parameter 5 Equivalent shield thickness (m)
5e7 # Parameter 6 Shield conductivity (S/m)ity
2 # number of frequency dependent dielectric models
# Inner dielectric relative permittivity model follows
1E7 # w normalisation constant
0 # a order, a coefficients follow below:
2.25
0 # b order, b coefficients follow below:
1.0
# Outer dielectric relative permittivity model follows
1E7 # w normalisation constant
0 # a order, a coefficients follow below:
2.50
0 # b order, b coefficients follow below:
1.0
1 # number of frequency dependent transfer impedance models
# Transfer impedance filter model follows
1.0 # w normalisation constant
1 # a order, a coefficients follow below:
1.62e-2 0.849e-9
0 # b order, b coefficients follow below:
1.0