TP_AWG_24_ESCC_3901019_V12.cable 3.7 KB
v3.0.3
twisted_pair
           2  # cable type number
           2  # Total Number of conductors
           1  # Number of external conductors
           2  # Total number of domains (including external domain)
           1  # Number of internal conductors
           1  # Number of internal domains
           4  # Number of cable parameters
   2.8210000000000003E-004
   1.1700000000000000E-003
   5.6499999999999996E-004
   33330000.000000000     
           1  # number of frequency dependent dielectric models
 # Dielectric filter number           1
   1.0000000000000000        # w normalisation constant
           0   # a order, a coefficients follow below:
   3.3999999999999999     
           0   # b order, b coefficients follow below:
   1.0000000000000000     
 # Conductor impedance models
           1  # Conductor impedance model type
   2.8210000000000003E-004  # conductor radius
   33330000.000000000       # conductivity
   1.5000000000000000       # Resistance_multiplication_factor
           1  # Conductor impedance model type
   2.8210000000000003E-004  # conductor radius
   33330000.000000000       # conductivity
   1.5000000000000000       # Resistance_multiplication_factor
 External to domain conductor current transformation matrix, MI
           3  Dimension of MI
  5.00000000E-01 -5.00000000E-01  0.00000000E+00
  1.00000000E+00  1.00000000E+00  0.00000000E+00
  1.00000000E+00  1.00000000E+00  1.00000000E+00
 External to domain conductor voltage transformation matrix, MV
           3  Dimension of MV
  1.00000000E+00 -1.00000000E+00  0.00000000E+00
  5.00000000E-01  5.00000000E-01 -1.00000000E+00
  0.00000000E+00  0.00000000E+00  1.00000000E+00
 Domain number           1
           2  # number of conductors
 High frequency Per-Unit-length Inductance Matrix, L
           1  Dimension of L
  5.43407265E-07
 High frequency Per-Unit-length Capacitance Matrix, C
           1  Dimension of C
  2.04754358E-11
 Per-Unit-length Impedance Matrix, Z
 Matrix of Laplace domain filters
           1    # dimension of Sfilter matrix
Element:   1   1
   1.0000000000000000        # w normalisation constant
           1   # a order, a coefficients follow below:
   0.0000000000000000        5.4340726470093728E-007
           0   # b order, b coefficients follow below:
   1.0000000000000000     
 Per-Unit-length Admittance Matrix, Y
 Matrix of Laplace domain filters
           1    # dimension of Sfilter matrix
Element:   1   1
   1.0000000000000000        # w normalisation constant
           1   # a order, a coefficients follow below:
   0.0000000000000000        2.0475435797925892E-011
           0   # b order, b coefficients follow below:
   1.0000000000000000     
  # Local reference conductor for internal domains
           2
           0
  # number of conductors in each domain
           2
           2
  # External conductor information and dielectric model
           1   conductor type
   4.2315000000000007E-004  conductor_radius 
   0.0000000000000000       conductor_width  
   0.0000000000000000       conductor_width2  
   0.0000000000000000       conductor_height 
   0.0000000000000000       conductor_ox     
   7.0604999999999995E-004  dielectric_radius
   0.0000000000000000       dielectric_width 
   0.0000000000000000       dielectric_height
   0.0000000000000000       dielectric_ox    
   1.0000000000000000        # w normalisation constant
           0   # a order, a coefficients follow below:
   3.3999999999999999     
           0   # b order, b coefficients follow below:
   1.0000000000000000     
  # Conductor labels
 Cable name: TP_AWG_24_ESCC_3901019_V12. type: twisted_pair. conductor 1 : Twisted pair wire 1
 Cable name: TP_AWG_24_ESCC_3901019_V12. type: twisted_pair. conductor 2 : Twisted pair wire 2