FD_coax.cable_spec
1.45 KB
#MOD_cable_lib_dir
./
Coax
2 # number of conductors
6 # number of parameters
4.2000E-04 # parameter 1: inner conductor radius
1.4700E-03 # parameter 2: shield radius
2.5000E-03 # parameter 3: outer dielectric radius
5.0000E+07 # parameter 4: inner wire conductivity
0.0000E+00 # parameter 5: shield conductor thickness
0.0000E+00 # parameter 6: shield conductivity
2 # number of frequency dependent parameters
# Inner dielectric relative permittivity model follows
10000000.000000000 # w normalisation constant
1 # a order, a coefficients follow below:
2.6000000000000001 2.0000000000000000
1 # b order, b coefficients follow below:
1.0000000000000000 1.0000000000000000
# Outer dielectric relative permittivity model follows
10000000.000000000 # w normalisation constant
1 # a order, a coefficients follow below:
2.3999999999999999 2.2000000000000002
1 # b order, b coefficients follow below:
1.0000000000000000 1.0000000000000000
1 # number of frequency dependent transfer impedance models
# Transfer impedance model follows
1.0000000000000000 # w normalisation constant
0 # a order, a coefficients follow below:
0.0000000000000000
0 # b order, b coefficients follow below:
1.0000000000000000
no_laplace