overshield.cable_spec
883 Bytes
#MOD_cable_lib_dir
.
overshield
1 # number of conductors
3 # number of parameters
0.005 # overshield radius
6.2500000000000015E-005 # overshield thickness
5e7 # overshield conductivity
0 # number of frequency dependent parameters
1 # number of frequency dependent transfer impedance models
# Transfer impedance model
628318530.71795857 # w normalisation constant
6 # a order, a coefficients follow below:
1.0187397735161184E-002 3.5842680574170149 85.114992402683157 526.07333453152262 1308.1309844214916 1460.8303657166405 709.46062984147602
5 # b order, b coefficients follow below:
1.0000000000000000 23.599449123864325 145.90222072648217 362.78999275303266 405.14016972906620 196.75864271144215