* Ngspice multi-conductor transmission line model * Created by Spice cable model builder v2.3.1 * * Transmission line subcircuit * * * End 1 nodes: * * node: 2 cable number: 1 type:cylindrical name:bare_wire conductor number 1 * node: 3 cable number: 2 type:coax name:coaxial_cable_01 conductor number 1 * node: 4 cable number: 2 type:coax name:coaxial_cable_01 conductor number 2 * * End 2 nodes: * * node: 5 cable number: 1 type:cylindrical name:bare_wire conductor number 1 * node: 6 cable number: 2 type:coax name:coaxial_cable_01 conductor number 1 * node: 7 cable number: 2 type:coax name:coaxial_cable_01 conductor number 2 * .subckt ZT_FD_Coax + 2 3 4 + 5 6 7 * * D.C. RESISTANCE END 1 * Rdc_c1_e1 2 8 5.000000E-09 Rdc_c2_e1 3 9 1.804478E-02 Rdc_c3_e1 4 1 5.000000E-02 * * D.C. RESISTANCE END 2 * Rdc_c1_e2 5 10 5.000000E-09 Rdc_c2_e2 6 11 1.804478E-02 Rdc_c3_e2 7 1 5.000000E-02 * * DOMAIN TRANSFORMATION END 1 * * * Domain decomposition Voltage sources used for current sensing * Vmeas_domain_decomp_c1_e1 8 14 Vmeas_domain_decomp_c2_e1 9 16 * * Domain decomposition Voltage controlled voltage sources (domain to conductor) * E_domain_decomp_c1_dc1_e1 14 15 12 1 -0.000000E+00 E_domain_decomp_c1_dc2_e1 15 1 13 1 1.000000E+00 E_domain_decomp_c2_dc1_e1 16 17 12 1 1.000000E+00 E_domain_decomp_c2_dc2_e1 17 1 13 1 -0.000000E+00 * * Domain decomposition Current controlled current sources (conductor to domain) * F_domain_decomp_c1_dc1_e1 1 12 Vmeas_domain_decomp_c1_e1 0.000000E+00 F_domain_decomp_c2_dc1_e1 1 12 Vmeas_domain_decomp_c2_e1 1.000000E+00 F_domain_decomp_c1_dc2_e1 1 13 Vmeas_domain_decomp_c1_e1 1.000000E+00 F_domain_decomp_c2_dc2_e1 1 13 Vmeas_domain_decomp_c2_e1 0.000000E+00 * * DOMAIN TRANSFORMATION END 2 * * * Domain decomposition Voltage sources used for current sensing * Vmeas_domain_decomp_c1_e2 10 20 Vmeas_domain_decomp_c2_e2 11 22 * * Domain decomposition Voltage controlled voltage sources (domain to conductor) * E_domain_decomp_c1_dc1_e2 20 21 18 1 -0.000000E+00 E_domain_decomp_c1_dc2_e2 21 1 19 1 1.000000E+00 E_domain_decomp_c2_dc1_e2 22 23 18 1 1.000000E+00 E_domain_decomp_c2_dc2_e2 23 1 19 1 -0.000000E+00 * * Domain decomposition Current controlled current sources (conductor to domain) * F_domain_decomp_c1_dc1_e2 1 18 Vmeas_domain_decomp_c1_e2 0.000000E+00 F_domain_decomp_c2_dc1_e2 1 18 Vmeas_domain_decomp_c2_e2 1.000000E+00 F_domain_decomp_c1_dc2_e2 1 19 Vmeas_domain_decomp_c1_e2 1.000000E+00 F_domain_decomp_c2_dc2_e2 1 19 Vmeas_domain_decomp_c2_e2 0.000000E+00 * * DOMAIN 1 * * * Modal Decomposition * * * Modal decomposition Voltage sources used for current sensing * Vmeas_mode_decomp_d1_c1_e1 12 25 * * Modal decomposition Voltage controlled voltage sources (mode to conductor) * E_mode_decomp_d1_c1_m1_e1 25 1 24 1 1.00000000E+00 * * Modal decomposition Current controlled current sources (conductor to mode) * F_mode_decomp_d1_c1_m1_e1 1 24 Vmeas_mode_decomp_d1_c1_e1 1.00000000E+00 * * Modal decomposition Voltage sources used for current sensing * Vmeas_mode_decomp_d1_c1_e2 18 27 * * Modal decomposition Voltage controlled voltage sources (mode to conductor) * E_mode_decomp_d1_c1_m1_e2 27 1 26 1 1.00000000E+00 * * Modal decomposition Current controlled current sources (conductor to mode) * F_mode_decomp_d1_c1_m1_e2 1 26 Vmeas_mode_decomp_d1_c1_e2 1.00000000E+00 * * Modal impedance: end1 * RZCm_d1_m1_e1 24 28 4.848574E+01 * * Modal impedance: end2 * RZCm_d1_m1_e2 26 29 4.848574E+01 * * Modal frequency dependent voltage controlled voltage source : end1 * E_m_d1_m1_e1 28 1 30 1 1.000000E+00 * * Modal frequency dependent voltage controlled voltage source : end2 * E_m_d1_m1_e2 29 1 31 1 1.000000E+00 * * Delay line for positive z propagation * T_pz_d1_m1_e1 31 1 32 1 Z0= 4.848574E+01 TD= 5.167553E-09 * * Delay line for negative z propagation * T_mz_d1_m1_e2 30 1 33 1 Z0= 4.848574E+01 TD= 5.167553E-09 * * Modal impedances on modal positive z propagation delay lines * RZC_pz_d1_m1_e1 31 1 4.848574E+01 * * Modal impedances on modal negative z propagation delay lines * RZC_mz_d1_m1_e2 30 1 4.848574E+01 * * Delay line frequency dependent controlled sources for positive z propagation * E_m_pz_d1_m1_e1 32 34 24 1 2.000000E+00 E_m_pz_d1_m1_e2 34 1 28 1 -1.000000E+00 * * Delay line frequency dependent controlled sources for negative z propagation * E_m_mz_d1_m1_e1 33 35 26 1 2.000000E+00 E_m_mz_d1_m1_e2 35 1 29 1 -1.000000E+00 * * DOMAIN 2 * * * Modal Decomposition * * * Modal decomposition Voltage sources used for current sensing * Vmeas_mode_decomp_d2_c1_e1 13 37 * * Modal decomposition Voltage controlled voltage sources (mode to conductor) * E_mode_decomp_d2_c1_m1_e1 37 1 36 1 1.00000000E+00 * * Modal decomposition Current controlled current sources (conductor to mode) * F_mode_decomp_d2_c1_m1_e1 1 36 Vmeas_mode_decomp_d2_c1_e1 1.00000000E+00 * * Modal decomposition Voltage sources used for current sensing * Vmeas_mode_decomp_d2_c1_e2 19 39 * * Modal decomposition Voltage controlled voltage sources (mode to conductor) * E_mode_decomp_d2_c1_m1_e2 39 1 38 1 1.00000000E+00 * * Modal decomposition Current controlled current sources (conductor to mode) * F_mode_decomp_d2_c1_m1_e2 1 38 Vmeas_mode_decomp_d2_c1_e2 1.00000000E+00 * * Modal impedance: end1 * RZCm_d2_m1_e1 36 40 3.910788E+02 * * Modal impedance: end2 * RZCm_d2_m1_e2 38 41 3.910788E+02 * * Modal frequency dependent voltage controlled voltage source : end1 * E_m_d2_m1_e1 40 1 42 1 1.000000E+00 * * Modal frequency dependent voltage controlled voltage source : end2 * E_m_d2_m1_e2 41 1 43 1 1.000000E+00 * * Delay line for positive z propagation * T_pz_d2_m1_e1 43 1 44 1 Z0= 3.910788E+02 TD= 3.335641E-09 * * Delay line for negative z propagation * T_mz_d2_m1_e2 42 1 45 1 Z0= 3.910788E+02 TD= 3.335641E-09 * * Modal impedances on modal positive z propagation delay lines * RZC_pz_d2_m1_e1 43 1 3.910788E+02 * * Modal impedances on modal negative z propagation delay lines * RZC_mz_d2_m1_e2 42 1 3.910788E+02 * * Delay line frequency dependent controlled sources for positive z propagation * E_m_pz_d2_m1_e1 44 46 36 1 2.000000E+00 E_m_pz_d2_m1_e2 46 1 40 1 -1.000000E+00 * * Delay line frequency dependent controlled sources for negative z propagation * E_m_mz_d2_m1_e1 45 47 38 1 2.000000E+00 E_m_mz_d2_m1_e2 47 1 41 1 -1.000000E+00 * .ends *