Blame view

TEST_CASES/FLEX_CABLE_3_EINC/flex_cable_3.cable_spec 1.55 KB
886c558b   Steve Greedy   SACAMOS Public Re...
1
2
3
4
#MOD_cable_lib_dir
.
flex_cable
3		# number of conductors
44c11f06   Chris Smartt   Include software ...
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
10		# number of parameters
5.0e-3          # parameter 1: dielectric width (x dimension)
1.25e-3  	# parameter 2: dielectric height (y dimension)
1               # parameter 3: number of rows of conductors
0.0e-3  	# parameter 4: row 1 centre offset x
0.0e-3  	# parameter 5: row 1 centre offset y
1.0e-3          # parameter 6: row 1 conductor width (x dimension)
0.25e-3         # parameter 7: row 1 conductor height (y dimension)
0.5e-3          # parameter 8: row 1 conductor separation
3               # parameter 9: row 1 number of conductors
0.0  	        # parameter 10: conductivity
1		# number of frequency dependent parameters
# dielectric relative permittivity model follows
   1E9        # w normalisation constant
           0   # a order, a coefficients follow below:
  2.2         
           0   # b order, b coefficients follow below:
  1.0      





#MOD_cable_lib_dir
.
flex_cable
3		# number of conductors
886c558b   Steve Greedy   SACAMOS Public Re...
32
33
34
35
36
37
38
39
40
41
42
43
44
45
6		# number of parameters
1.0e-3  	# parameter 1: conductor width (x dimension)
0.25e-3  	# parameter 2: conductor height (y dimension)
0.5e-3  	# parameter 3: conductor separation (x dimension)
0.5e-3  	# parameter 4: dielectric offset x
0.5e-3  	# parameter 5: dielectric offset y
0.0  	        # parameter 6: conductivity
1		# number of frequency dependent parameters
# dielectric relative permittivity model follows
   1E9        # w normalisation constant
           0   # a order, a coefficients follow below:
  2.2         
           0   # b order, b coefficients follow below:
  1.0