Blame view

EXAMPLE_MOD/CABLE/twinax_cable.cable_spec 1.16 KB
a4086fdd   Steve Greedy   Add Example MOD
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
# MOD_cable_lib_dir 
../MOD_WEB_EXAMPLES/CABLE/
Twinax
3 	#number of conductors 
8 	#number of parameters 
0.25e-3 	# parameter 1: inner conductor radius (m)
0.45e-3 	# parameter 2: inner dielectric radius (m)
1.0e-3 	# parameter 3: inner conductor separation (m)
2.0e-3 	# parameter 4: shield radius (m)
0.0 	# parameter 5: shield thickness (m)
3.0e-3 	# parameter 6: outer dielectric radius (m)
5e7 	# parameter 7: inner conductor electric conductivity (m)
5e7 	# parameter 8: shield electric conductivity (m)
2 	#number of frequency dependent parameters 
# Inner dielectric relative permittivity
1e7 	# w normalisation constant
0 # a order, a coefficents follow below
2.25 
0 # b order, b coefficents follow below
1.0 
#  Outer dielectric relative permittivity
1e7 	# w normalisation constant
0 	# a order, a coefficents follow below
2.25 
0 	# b order, b coefficents follow below
1.0 
1 # number of frequency dependent transfer impedance models
#  Transfer impedance model 
1 # angular frequency normalisation
1 # order of numerator model
0.1 1e-9 	# list of numerator coefficients a0 a1 a2... 
0 # order of denominator model
1 # list of denominator coefficients b0 b1 b2... 
no_laplace