Blame view

EXAMPLE_MOD/SPICE/ZT_FD_Coax_NGspice.lib 7.68 KB
a4086fdd   Steve Greedy   Add Example MOD
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
* Ngspice multi-conductor transmission line model
* Created by Spice cable model builder v2.3.1
*
* Transmission line subcircuit
*
*
* End 1 nodes:
*
* node:  2 cable number:  1 type:cylindrical name:bare_wire  conductor number  1
* node:  3 cable number:  2 type:coax name:coaxial_cable_01  conductor number  1
* node:  4 cable number:  2 type:coax name:coaxial_cable_01  conductor number  2
*
* End 2 nodes:
*
* node:  5 cable number:  1 type:cylindrical name:bare_wire  conductor number  1
* node:  6 cable number:  2 type:coax name:coaxial_cable_01  conductor number  1
* node:  7 cable number:  2 type:coax name:coaxial_cable_01  conductor number  2
*
.subckt  ZT_FD_Coax
+     2     3     4
+     5     6     7
*
* D.C. RESISTANCE END 1
*
Rdc_c1_e1                          2     8    5.000000E-09
Rdc_c2_e1                          3     9    1.804478E-02
Rdc_c3_e1                          4     1    5.000000E-02
*
* D.C. RESISTANCE END 2
*
Rdc_c1_e2                          5    10    5.000000E-09
Rdc_c2_e2                          6    11    1.804478E-02
Rdc_c3_e2                          7     1    5.000000E-02
*
* DOMAIN TRANSFORMATION END 1
*
*
* Domain decomposition Voltage sources used for current sensing
*
Vmeas_domain_decomp_c1_e1          8    14
Vmeas_domain_decomp_c2_e1          9    16
*
* Domain decomposition Voltage controlled voltage sources (domain to conductor)
*
E_domain_decomp_c1_dc1_e1         14    15    12     1   -0.000000E+00
E_domain_decomp_c1_dc2_e1         15     1    13     1    1.000000E+00
E_domain_decomp_c2_dc1_e1         16    17    12     1    1.000000E+00
E_domain_decomp_c2_dc2_e1         17     1    13     1   -0.000000E+00
*
* Domain decomposition Current controlled current sources (conductor to domain)
*
F_domain_decomp_c1_dc1_e1          1    12 Vmeas_domain_decomp_c1_e1         0.000000E+00
F_domain_decomp_c2_dc1_e1          1    12 Vmeas_domain_decomp_c2_e1         1.000000E+00
F_domain_decomp_c1_dc2_e1          1    13 Vmeas_domain_decomp_c1_e1         1.000000E+00
F_domain_decomp_c2_dc2_e1          1    13 Vmeas_domain_decomp_c2_e1         0.000000E+00
*
* DOMAIN TRANSFORMATION END 2
*
*
* Domain decomposition Voltage sources used for current sensing
*
Vmeas_domain_decomp_c1_e2         10    20
Vmeas_domain_decomp_c2_e2         11    22
*
* Domain decomposition Voltage controlled voltage sources (domain to conductor)
*
E_domain_decomp_c1_dc1_e2         20    21    18     1   -0.000000E+00
E_domain_decomp_c1_dc2_e2         21     1    19     1    1.000000E+00
E_domain_decomp_c2_dc1_e2         22    23    18     1    1.000000E+00
E_domain_decomp_c2_dc2_e2         23     1    19     1   -0.000000E+00
*
* Domain decomposition Current controlled current sources (conductor to domain)
*
F_domain_decomp_c1_dc1_e2          1    18 Vmeas_domain_decomp_c1_e2         0.000000E+00
F_domain_decomp_c2_dc1_e2          1    18 Vmeas_domain_decomp_c2_e2         1.000000E+00
F_domain_decomp_c1_dc2_e2          1    19 Vmeas_domain_decomp_c1_e2         1.000000E+00
F_domain_decomp_c2_dc2_e2          1    19 Vmeas_domain_decomp_c2_e2         0.000000E+00
*
* DOMAIN      1
*
*
* Modal Decomposition
*
*
* Modal decomposition Voltage sources used for current sensing
*
Vmeas_mode_decomp_d1_c1_e1        12    25
*
* Modal decomposition Voltage controlled voltage sources (mode to conductor)
*
E_mode_decomp_d1_c1_m1_e1         25     1    24     1    1.00000000E+00
*
* Modal decomposition Current controlled current sources (conductor to mode)
*
F_mode_decomp_d1_c1_m1_e1          1    24 Vmeas_mode_decomp_d1_c1_e1        1.00000000E+00
*
* Modal decomposition Voltage sources used for current sensing
*
Vmeas_mode_decomp_d1_c1_e2        18    27
*
* Modal decomposition Voltage controlled voltage sources (mode to conductor)
*
E_mode_decomp_d1_c1_m1_e2         27     1    26     1    1.00000000E+00
*
* Modal decomposition Current controlled current sources (conductor to mode)
*
F_mode_decomp_d1_c1_m1_e2          1    26 Vmeas_mode_decomp_d1_c1_e2        1.00000000E+00
*
* Modal impedance: end1
*
RZCm_d1_m1_e1                     24    28    4.848574E+01
*
* Modal impedance: end2
*
RZCm_d1_m1_e2                     26    29    4.848574E+01
*
* Modal frequency dependent voltage controlled voltage source : end1
*
E_m_d1_m1_e1                      28     1    30     1    1.000000E+00
*
* Modal frequency dependent voltage controlled voltage source : end2
*
E_m_d1_m1_e2                      29     1    31     1    1.000000E+00
*
* Delay line for positive z propagation
*
T_pz_d1_m1_e1                     31     1    32     1 Z0=    4.848574E+01 TD=    5.167553E-09
*
* Delay line for negative z propagation
*
T_mz_d1_m1_e2                     30     1    33     1 Z0=    4.848574E+01 TD=    5.167553E-09
*
* Modal impedances on modal positive z propagation delay lines
*
RZC_pz_d1_m1_e1                   31     1    4.848574E+01
*
* Modal impedances on modal negative z propagation delay lines
*
RZC_mz_d1_m1_e2                   30     1    4.848574E+01
*
* Delay line frequency dependent controlled sources for positive z propagation
*
E_m_pz_d1_m1_e1                   32    34    24     1    2.000000E+00
E_m_pz_d1_m1_e2                   34     1    28     1   -1.000000E+00
*
* Delay line frequency dependent controlled sources for negative z propagation
*
E_m_mz_d1_m1_e1                   33    35    26     1    2.000000E+00
E_m_mz_d1_m1_e2                   35     1    29     1   -1.000000E+00
*
* DOMAIN      2
*
*
* Modal Decomposition
*
*
* Modal decomposition Voltage sources used for current sensing
*
Vmeas_mode_decomp_d2_c1_e1        13    37
*
* Modal decomposition Voltage controlled voltage sources (mode to conductor)
*
E_mode_decomp_d2_c1_m1_e1         37     1    36     1    1.00000000E+00
*
* Modal decomposition Current controlled current sources (conductor to mode)
*
F_mode_decomp_d2_c1_m1_e1          1    36 Vmeas_mode_decomp_d2_c1_e1        1.00000000E+00
*
* Modal decomposition Voltage sources used for current sensing
*
Vmeas_mode_decomp_d2_c1_e2        19    39
*
* Modal decomposition Voltage controlled voltage sources (mode to conductor)
*
E_mode_decomp_d2_c1_m1_e2         39     1    38     1    1.00000000E+00
*
* Modal decomposition Current controlled current sources (conductor to mode)
*
F_mode_decomp_d2_c1_m1_e2          1    38 Vmeas_mode_decomp_d2_c1_e2        1.00000000E+00
*
* Modal impedance: end1
*
RZCm_d2_m1_e1                     36    40    3.910788E+02
*
* Modal impedance: end2
*
RZCm_d2_m1_e2                     38    41    3.910788E+02
*
* Modal frequency dependent voltage controlled voltage source : end1
*
E_m_d2_m1_e1                      40     1    42     1    1.000000E+00
*
* Modal frequency dependent voltage controlled voltage source : end2
*
E_m_d2_m1_e2                      41     1    43     1    1.000000E+00
*
* Delay line for positive z propagation
*
T_pz_d2_m1_e1                     43     1    44     1 Z0=    3.910788E+02 TD=    3.335641E-09
*
* Delay line for negative z propagation
*
T_mz_d2_m1_e2                     42     1    45     1 Z0=    3.910788E+02 TD=    3.335641E-09
*
* Modal impedances on modal positive z propagation delay lines
*
RZC_pz_d2_m1_e1                   43     1    3.910788E+02
*
* Modal impedances on modal negative z propagation delay lines
*
RZC_mz_d2_m1_e2                   42     1    3.910788E+02
*
* Delay line frequency dependent controlled sources for positive z propagation
*
E_m_pz_d2_m1_e1                   44    46    36     1    2.000000E+00
E_m_pz_d2_m1_e2                   46     1    40     1   -1.000000E+00
*
* Delay line frequency dependent controlled sources for negative z propagation
*
E_m_mz_d2_m1_e1                   45    47    38     1    2.000000E+00
E_m_mz_d2_m1_e2                   47     1    41     1   -1.000000E+00
*
.ends
*